Assessing zinc from a nail clipping using mono-energetic portable X-ray fluorescence. (March 2019)
- Record Type:
- Journal Article
- Title:
- Assessing zinc from a nail clipping using mono-energetic portable X-ray fluorescence. (March 2019)
- Main Title:
- Assessing zinc from a nail clipping using mono-energetic portable X-ray fluorescence
- Authors:
- Fleming, David E.B.
Crook, Samantha L.
Evans, Colby T. - Abstract:
- Abstract: A mono-energetic X-ray beam from a portable X-ray fluorescence device was used to excite characteristic X-rays from zinc in a series of nail clipping phantoms. Twenty nail clipping phantoms having equal zinc concentrations of ~40 µg/g, but with different physical characteristics, were measured individually for 300 s using a small diameter (~1 mm) X-ray beam. Energy spectra obtained from the measurements were analyzed using PyMca software. Zinc signal size varied widely between the different clippings, with a relative standard deviation of 41% observed in the combined signal from zinc Kα and Kβ characteristic X-rays. Three different normalization approaches were introduced to account for variation in the amounts of sample interrogated by the X-ray beam. All three approaches produced similar results, and successfully reduced the relative standard deviation to between 12% and 13%. A clear trend was still observed, however, between the normalized zinc signal and the thickness of clipping measured. To account for this effect, normalized signals were adjusted to calculate "thickness-corrected" values. The relative standard deviation of these thickness-corrected values was 6.2%. Reproducibility of measurement from individual clippings was excellent, with relative standard deviations on the order of 1%, with or without normalization. Overall, this new method of measuring zinc in nail shows promise for the assessment of zinc status in humans using a portable device. TheAbstract: A mono-energetic X-ray beam from a portable X-ray fluorescence device was used to excite characteristic X-rays from zinc in a series of nail clipping phantoms. Twenty nail clipping phantoms having equal zinc concentrations of ~40 µg/g, but with different physical characteristics, were measured individually for 300 s using a small diameter (~1 mm) X-ray beam. Energy spectra obtained from the measurements were analyzed using PyMca software. Zinc signal size varied widely between the different clippings, with a relative standard deviation of 41% observed in the combined signal from zinc Kα and Kβ characteristic X-rays. Three different normalization approaches were introduced to account for variation in the amounts of sample interrogated by the X-ray beam. All three approaches produced similar results, and successfully reduced the relative standard deviation to between 12% and 13%. A clear trend was still observed, however, between the normalized zinc signal and the thickness of clipping measured. To account for this effect, normalized signals were adjusted to calculate "thickness-corrected" values. The relative standard deviation of these thickness-corrected values was 6.2%. Reproducibility of measurement from individual clippings was excellent, with relative standard deviations on the order of 1%, with or without normalization. Overall, this new method of measuring zinc in nail shows promise for the assessment of zinc status in humans using a portable device. The method is sensitive, rapid, and requires only a single nail clipping. Highlights: Mono-energetic portable X-ray fluorescence used to assess zinc in nail clipping phantoms. Normalization techniques and correction for thickness reduced variability in data. This X-ray fluorescence method was sensitive and required only a single nail clipping. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 145(2019:Mar.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 145(2019:Mar.)
- Issue Display:
- Volume 145 (2019)
- Year:
- 2019
- Volume:
- 145
- Issue Sort Value:
- 2019-0145-0000-0000
- Page Start:
- 170
- Page End:
- 175
- Publication Date:
- 2019-03
- Subjects:
- Mono-energetic X-ray -- Portable X-ray fluorescence -- Zinc -- Nail clippings -- Biomarker
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2018.12.033 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9569.xml