Evaluation of Two Protocols to Measure the Accuracy of Fixed Dental Prostheses: An In Vitro Study. Issue 2 (2nd February 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of Two Protocols to Measure the Accuracy of Fixed Dental Prostheses: An In Vitro Study. Issue 2 (2nd February 2017)
- Main Title:
- Evaluation of Two Protocols to Measure the Accuracy of Fixed Dental Prostheses: An In Vitro Study
- Authors:
- Schönberger, Joana
Erdelt, Kurt‐Jürgen
Bäumer, Daniel
Beuer, Florian - Abstract:
- Abstract: Purpose: The aim of this in vitro study was to compare two measurement protocols of the internal and marginal fit of three‐unit zirconia fixed dental prostheses (FDPs). Materials and Methods: Forty‐four FDPs were fabricated for standardized dies by two laboratory CAD/CAM systems: Cercon (n = 22) and Ceramill (n = 22). The fitting was tested using a replica technique (RT = technique 1) with a light‐body silicone stabilized with heavy‐body material. After producing the replicas, cross‐sections were made in the buccolingual and mesiodistal directions. FDPs were cemented on definitive dies, embedded, and sectioned (CST = technique 2). The marginal and internal fits were measured under an optical microscope at 50x magnification with a special software program. Data evaluation was performed according to prior studies at a level of significance of 5%. Results: The mean internal gap width was 51 ± 36 μm for the RT and 52 ± 35 μm for the cross‐section technique (CST) ( p = 0.74). The mean marginal gap width was 27 ± 18 μm for RT and 30 ± 19 μm for CST ( p = 0.19). Statistical tests showed no significant differences ( p > 0.05). Conclusions: Both techniques can be used for fit evaluation; however, the noninvasive RT is suitable for clinical use.
- Is Part Of:
- Journal of prosthodontics. Volume 28:Issue 2(2019)
- Journal:
- Journal of prosthodontics
- Issue:
- Volume 28:Issue 2(2019)
- Issue Display:
- Volume 28, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 2
- Issue Sort Value:
- 2019-0028-0002-0000
- Page Start:
- e599
- Page End:
- e603
- Publication Date:
- 2017-02-02
- Subjects:
- Computer‐aided design/computer‐aided manufacturing -- pre‐sintered zirconia -- marginal and internal fit measurement -- replica technique -- cross‐section technique
Prosthodontics -- Periodicals
Dental implants -- Periodicals
Dentistry -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-849X ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jopr ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jopr.12583 ↗
- Languages:
- English
- ISSNs:
- 1059-941X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.920000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9547.xml