The fabrication of poly (polyethylene glycol diacrylate) monolithic porous layer open tubular (mono‐PLOT) columns and applications in hydrophilic interaction chromatography and capillary gas chromatography for small molecules. Issue 4 (25th January 2019)
- Record Type:
- Journal Article
- Title:
- The fabrication of poly (polyethylene glycol diacrylate) monolithic porous layer open tubular (mono‐PLOT) columns and applications in hydrophilic interaction chromatography and capillary gas chromatography for small molecules. Issue 4 (25th January 2019)
- Main Title:
- The fabrication of poly (polyethylene glycol diacrylate) monolithic porous layer open tubular (mono‐PLOT) columns and applications in hydrophilic interaction chromatography and capillary gas chromatography for small molecules
- Authors:
- Chang, Feng
Yue, Yunfang
Yang, Zihui
Huang, Si
Liu, Zhihua
Wang, Kunmiao
Peng, Yan
Chen, Yingzhuang
Ma, Ming
Chen, Bo - Abstract:
- Abstract: The easy shrinkage and swelling of polymer monolithic column when exposed to mobile phase with different polarity is a problem that cannot be ignored. To overcome this drawback, a convenient aqueous two‐phase polymerization approach was used to prepare poly (polyethylene glycol diacrylate, PEGDA) monolithic porous layer open tubular (mono‐PLOT) columns (150 μm). The poly(PEGDA) mono‐PLOT column with homogeneous polymer porous layer was synthesized successfully. A maximum plate number of 41, 500 plates per meter for allyl thiourea was obtained under a velocity of 1.8 mm/s. Several kinds of polar molecule were separated on the proposed mono‐PLOT column and a typical hydrophilic interaction retention mechanism was observed. High speed separation of benzoic acids was also carried out, baseline separation of five benzoic acids was successfully achieved within 5 min with a 70 cm mono‐PLOT column at 50°C. Furthermore, the resulting PLOT column was also successfully applied to separate standard analytes of three DNA oxidative damage products and RNA‐modified nucleosides and four chlorophenols. At last, the column could separate alcohols, alkanes, and aromatic isomers via GC. It had more than 20, 000 plates per meter for butanol – higher than commercial coatings open tubular columns.
- Is Part Of:
- Electrophoresis. Volume 40:Issue 4(2019)
- Journal:
- Electrophoresis
- Issue:
- Volume 40:Issue 4(2019)
- Issue Display:
- Volume 40, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 40
- Issue:
- 4
- Issue Sort Value:
- 2019-0040-0004-0000
- Page Start:
- 521
- Page End:
- 529
- Publication Date:
- 2019-01-25
- Subjects:
- Aqueous two‐phase polymerization -- Capillary liquid chromatography -- Gas chromatography -- Hydrophilic chromatography -- Porous layer open tubular
Electrophoresis -- Periodicals
Electrophoresis -- Periodicals
541.372 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2683 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elps.201800410 ↗
- Languages:
- English
- ISSNs:
- 0173-0835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3706.378000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9531.xml