Development of a quantitative method for assessment of dose in in vitro evaluations using a VITROCELL® VC10® smoke exposure system. (April 2019)
- Record Type:
- Journal Article
- Title:
- Development of a quantitative method for assessment of dose in in vitro evaluations using a VITROCELL® VC10® smoke exposure system. (April 2019)
- Main Title:
- Development of a quantitative method for assessment of dose in in vitro evaluations using a VITROCELL® VC10® smoke exposure system
- Authors:
- Keyser, Brian M.
Leverette, Robert
Fowler, Kathy
Fields, Wanda
Hargreaves, Victoria
Reeve, Lesley
Bombick, Betsy - Abstract:
- Abstract: The assessment of potential cytotoxicity or genotoxicity of combustible tobacco products has historically been performed using partitioned exposures (i.e. total particulate matter [TPM], gas vapor phase [GVP]) rather than whole smoke. The VITROCELL® VC10® smoke exposure system offers multiple platforms for air liquid interface (ALI) or air agar interface (AAI) exposure to mimic in vivo-like conditions for assessing the toxicological impact of whole smoke using in vitro assays (e.g. cytotoxicity, mutagenicity and DNA modifications). The aims of this study were to investigate dosimetry during whole smoke exposure in the VITROCELL® VC10® smoking robot using quartz crystal microbalances (QCMs) and to support the use of photometers for concurrent assessment of 'dose' during whole smoke exposures. QCM results showed consistent deposition across different exposure chambers, between dilution bars, experiments and modules. Higher levels of variation were noted at higher airflows (i.e., >8 L/min). Dosimetry assessed using photometers also showed a high level of consistency between experiments, with no notable impact on deposition on the QCM when the photometers were placed 'in-line' between the dilution bar and the exposure module. However, the use of photometers alone may be not be sufficient to estimate deposition; the predictability of the data-generated equation was poor. Further development of dosimetry methodology and information for use in validated in vitroAbstract: The assessment of potential cytotoxicity or genotoxicity of combustible tobacco products has historically been performed using partitioned exposures (i.e. total particulate matter [TPM], gas vapor phase [GVP]) rather than whole smoke. The VITROCELL® VC10® smoke exposure system offers multiple platforms for air liquid interface (ALI) or air agar interface (AAI) exposure to mimic in vivo-like conditions for assessing the toxicological impact of whole smoke using in vitro assays (e.g. cytotoxicity, mutagenicity and DNA modifications). The aims of this study were to investigate dosimetry during whole smoke exposure in the VITROCELL® VC10® smoking robot using quartz crystal microbalances (QCMs) and to support the use of photometers for concurrent assessment of 'dose' during whole smoke exposures. QCM results showed consistent deposition across different exposure chambers, between dilution bars, experiments and modules. Higher levels of variation were noted at higher airflows (i.e., >8 L/min). Dosimetry assessed using photometers also showed a high level of consistency between experiments, with no notable impact on deposition on the QCM when the photometers were placed 'in-line' between the dilution bar and the exposure module. However, the use of photometers alone may be not be sufficient to estimate deposition; the predictability of the data-generated equation was poor. Further development of dosimetry methodology and information for use in validated in vitro biological test methods is needed to facilitate on-going aerosol-based research and relative assessment. Highlights: A dose-determining method was developed using the VITROCELL® VC10® system Measured dose was consistent between exposure chambers and replicate experiments Dose assessments were consistent using Quartz Crystal Microbalances (QCM) and photometers at lower airflows At higher airflows, dose assessment at air-liquid-interface and air-agar-interface using photometers is recommended … (more)
- Is Part Of:
- Toxicology in vitro. Volume 56(2019)
- Journal:
- Toxicology in vitro
- Issue:
- Volume 56(2019)
- Issue Display:
- Volume 56, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 56
- Issue:
- 2019
- Issue Sort Value:
- 2019-0056-2019-0000
- Page Start:
- 19
- Page End:
- 29
- Publication Date:
- 2019-04
- Subjects:
- Whole smoke -- VitroCell smoke exposure system -- Aerosol dosimetry -- Cytotoxicity -- Mutagenicity
Toxicity testing -- In vitro -- Periodicals
Toxicology -- Periodicals
615.9 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08872333 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.tiv.2018.12.010 ↗
- Languages:
- English
- ISSNs:
- 0887-2333
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8873.043400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: