Rationale, design, and endpoints of the 'DEvice-Detected CArdiac Tachyarrhythmic Events and Sleep-disordered Breathing (DEDiCATES)' study: Prospective multicenter observational study of device-detected tachyarrhythmia and sleep-disordered breathing. (1st April 2019)
- Record Type:
- Journal Article
- Title:
- Rationale, design, and endpoints of the 'DEvice-Detected CArdiac Tachyarrhythmic Events and Sleep-disordered Breathing (DEDiCATES)' study: Prospective multicenter observational study of device-detected tachyarrhythmia and sleep-disordered breathing. (1st April 2019)
- Main Title:
- Rationale, design, and endpoints of the 'DEvice-Detected CArdiac Tachyarrhythmic Events and Sleep-disordered Breathing (DEDiCATES)' study: Prospective multicenter observational study of device-detected tachyarrhythmia and sleep-disordered breathing
- Authors:
- Gwag, Hye Bin
Park, Youngjun
Lee, Seong Soo
Kim, June Soo
Park, Kyoung-Min
On, Young Keun
Lee, Dae In
Shin, Dong-Gu
Choi, Eue-Keun
Kang, Gu-Hyun
Park, Hyoung-Seob
Park, Hyung Wook
Shim, Jae-Min
Uhm, Jae-Sun
Kim, Jun
Kim, Jun-Hyung
Kang, Ki-Woon
Park, Sang Weon
Oh, Yong-Seog
Cho, Youngjin
Lee, Young Soo
Park, Seung-Jung - Abstract:
- Abstract: Background: Few studies have investigated the prognostic value of cardiac implantable electronic device (CIED)-detection of sleep-disordered breathing (SDB) for risk stratification of cardiovascular events. In the Device-Detected CArdiac Tachyarrhythmic events and Sleep-disordered breathing (DEDiCATES) study, we aim to determine whether device-detected SDB events are associated with increased risk of cardiac arrhythmias or other cardiovascular outcomes. Methods and design: Six-hundred patients (300 patients with low-voltage pacing devices and 300 with high-voltage defibrillator devices) who have dual chamber CIEDs with AP Scan™ function (Boston Scientific Inc., Marlborough, MA, USA) are planned to be enrolled in this study. AP Scan reports the average number of sleep disturbance events per hour per night in the form of a Respiratory Disturbance Index (RDI). The daily RDI values are to be used for quantitative measurement of the severity and burden of SDB. CIED-detected atrial high rate episodes (AHREs) and clinical atrial tachyarrhythmia will be assessed as the primary outcomes over a follow-up period of 2 years. Correlations between CIED-detected SDB and AHRE burdens will be analyzed. The secondary outcomes are CIED-detected or clinical ventricular arrhythmic events, stroke, heart failure hospitalization, mortality, and quality of life. Conclusion: This study will determine the prognostic value of automated diagnostic function of CIED for SDB, which will help toAbstract: Background: Few studies have investigated the prognostic value of cardiac implantable electronic device (CIED)-detection of sleep-disordered breathing (SDB) for risk stratification of cardiovascular events. In the Device-Detected CArdiac Tachyarrhythmic events and Sleep-disordered breathing (DEDiCATES) study, we aim to determine whether device-detected SDB events are associated with increased risk of cardiac arrhythmias or other cardiovascular outcomes. Methods and design: Six-hundred patients (300 patients with low-voltage pacing devices and 300 with high-voltage defibrillator devices) who have dual chamber CIEDs with AP Scan™ function (Boston Scientific Inc., Marlborough, MA, USA) are planned to be enrolled in this study. AP Scan reports the average number of sleep disturbance events per hour per night in the form of a Respiratory Disturbance Index (RDI). The daily RDI values are to be used for quantitative measurement of the severity and burden of SDB. CIED-detected atrial high rate episodes (AHREs) and clinical atrial tachyarrhythmia will be assessed as the primary outcomes over a follow-up period of 2 years. Correlations between CIED-detected SDB and AHRE burdens will be analyzed. The secondary outcomes are CIED-detected or clinical ventricular arrhythmic events, stroke, heart failure hospitalization, mortality, and quality of life. Conclusion: This study will determine the prognostic value of automated diagnostic function of CIED for SDB, which will help to improve the cardiovascular prognoses of CIED patients by enabling convenient and accurate assessments of SDB events. Highlights: Cardiac implantable electronic devices can detect sleep-disordered breathing (SDB). Few studied the prognostic value of device-detected SDB in cardiovascular risks. We aim to determine the association between device-detected SDB and cardiac events. … (more)
- Is Part Of:
- International journal of cardiology. Volume 280(2019)
- Journal:
- International journal of cardiology
- Issue:
- Volume 280(2019)
- Issue Display:
- Volume 280, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 280
- Issue:
- 2019
- Issue Sort Value:
- 2019-0280-2019-0000
- Page Start:
- 69
- Page End:
- 73
- Publication Date:
- 2019-04-01
- Subjects:
- Cardiac implantable electronic device -- Sleep-disordered breathing -- Obstructive sleep apnea -- Arrhythmia
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2019.01.045 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9545.xml