A comparison of the efficacy of multiple ultraviolet light room decontamination devices in a radiology procedure room. (30th January 2019)
- Record Type:
- Journal Article
- Title:
- A comparison of the efficacy of multiple ultraviolet light room decontamination devices in a radiology procedure room. (30th January 2019)
- Main Title:
- A comparison of the efficacy of multiple ultraviolet light room decontamination devices in a radiology procedure room
- Authors:
- Cadnum, Jennifer L.
Jencson, Annette L.
Gestrich, Scott A.
Livingston, Scott H.
Karaman, Boris A.
Benner, Kevin J.
Wilson, Brigid M.
Donskey, Curtis J. - Abstract:
- Abstract: Objective: To evaluate the efficacy of multiple ultraviolet (UV) light decontamination devices in a radiology procedure room. Design: Laboratory evaluation. Methods: We compared the efficacy of 8 UV decontamination devices with a 4-minute UV exposure time in reducing recovery of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores on steel disk carriers placed at 5 sites on a computed tomography patient table. Analysis of variance was used to compare reductions for the different devices. A spectrometer was used to obtain irradiance measurements for the devices. Results: Four standard vertical tower low-pressure mercury devices achieved 2 log10 CFU or greater reductions in VRE and MRSA and ~1 log10 CFU reductions in C. difficile spores, whereas a pulsed-xenon device resulted in less reduction in the pathogens ( P <.001). In comparison to the vertical tower low-pressure mercury devices, equal or greater reductions in the pathogens were achieved by 3 nonstandard low-pressure mercury devices that included either adjustable bulbs that could be oriented directly over the exam table, a robotic base allowing movement along the side of the table during operation, or 3 vertical towers operated simultaneously. The low-pressure mercury devices produced primarily UV-C light, whereas the pulsed-xenon device produced primarily UV-A and UV-B light. The time required to move the devices from the corner of theAbstract: Objective: To evaluate the efficacy of multiple ultraviolet (UV) light decontamination devices in a radiology procedure room. Design: Laboratory evaluation. Methods: We compared the efficacy of 8 UV decontamination devices with a 4-minute UV exposure time in reducing recovery of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores on steel disk carriers placed at 5 sites on a computed tomography patient table. Analysis of variance was used to compare reductions for the different devices. A spectrometer was used to obtain irradiance measurements for the devices. Results: Four standard vertical tower low-pressure mercury devices achieved 2 log10 CFU or greater reductions in VRE and MRSA and ~1 log10 CFU reductions in C. difficile spores, whereas a pulsed-xenon device resulted in less reduction in the pathogens ( P <.001). In comparison to the vertical tower low-pressure mercury devices, equal or greater reductions in the pathogens were achieved by 3 nonstandard low-pressure mercury devices that included either adjustable bulbs that could be oriented directly over the exam table, a robotic base allowing movement along the side of the table during operation, or 3 vertical towers operated simultaneously. The low-pressure mercury devices produced primarily UV-C light, whereas the pulsed-xenon device produced primarily UV-A and UV-B light. The time required to move the devices from the corner of the room and set up for operation varied from 18 to 59 seconds. Conclusions: Many currently available UV devices could provide an effective and efficient adjunct to manual cleaning and disinfection in radiology procedure rooms. … (more)
- Is Part Of:
- Infection control and hospital epidemiology. Volume 40:Number 2(2019)
- Journal:
- Infection control and hospital epidemiology
- Issue:
- Volume 40:Number 2(2019)
- Issue Display:
- Volume 40, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 40
- Issue:
- 2
- Issue Sort Value:
- 2019-0040-0002-0000
- Page Start:
- 158
- Page End:
- 163
- Publication Date:
- 2019-01-30
- Subjects:
- Nosocomial infections -- Epidemiology -- Periodicals
Health facilities -- Sanitation -- Periodicals
Hospital buildings -- Sanitation -- Periodicals
Cross Infection -- Periodicals
Epidemiology -- Periodicals
Hospitals -- Periodicals
Infection Control -- Periodicals
614.44 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00004848-000000000-00000 ↗
http://journals.cambridge.org/action/displayJournal?jid=ICE ↗
http://www.ichejournal.com/default.asp ↗
http://www.journals.uchicago.edu/ICHE/home.html ↗
http://www.jstor.org/journals/0899823X.html ↗ - DOI:
- 10.1017/ice.2018.296 ↗