Timing of cardiac resynchronization therapy device implantation in heart failure patients and its association with outcomes. Issue 2 (26th December 2018)
- Record Type:
- Journal Article
- Title:
- Timing of cardiac resynchronization therapy device implantation in heart failure patients and its association with outcomes. Issue 2 (26th December 2018)
- Main Title:
- Timing of cardiac resynchronization therapy device implantation in heart failure patients and its association with outcomes
- Authors:
- Goldstein, Sarah A.
Mentz, Robert J.
Hellkamp, Anne S.
Randolph, Tiffany C.
Fonarow, Gregg C.
Hernandez, Adrian
Yancy, Clyde W.
Al‐Khatib, Sana M. - Abstract:
- Abstract : Background: When used in appropriately selected heart failure (HF) patients, cardiac resynchronization therapy (CRT) reduces mortality and hospitalization. It is not understood whether CRT implantation during hospitalization for HF is associated with similar benefits. Hypothesis: Timing of CRT implantation relative to hospitalization for HF is associated with clinical outcomes. Methods: This analysis included patients eligible for CRT and discharged alive between January 2005 and December 2012 from 388 hospitals in Get With The Guidelines‐HF. Participants were linked with Centers for Medicare and Medicaid Services data to evaluate outcomes of all‐cause mortality and HF re‐hospitalization based on CRT status (present on admission, placed during hospitalization, and prescribed at discharge; reference = no CRT). Results: Of 15 619 CRT‐eligible HF patients, 2408 (15%) had CRT on admission, 1269 (8%) underwent CRT implantation during hospitalization and 643 (4%) had CRT prescribed at discharge. Compared with patients without CRT, mortality was lower in those who received CRT implantation during HF hospitalization (adjusted hazard ratio [HR] 0.63; P < 0.0001) and those prescribed CRT at discharge (adjusted HR 0.78; P = 0.048). A reduction in HF re‐hospitalization was observed in patients with CRT implanted during hospitalization (adjusted HR 0.64; P < 0.0001), but not in those who were prescribed CRT at discharge (adjusted HR 1.02; P = 0.77). Conclusion: CRTAbstract : Background: When used in appropriately selected heart failure (HF) patients, cardiac resynchronization therapy (CRT) reduces mortality and hospitalization. It is not understood whether CRT implantation during hospitalization for HF is associated with similar benefits. Hypothesis: Timing of CRT implantation relative to hospitalization for HF is associated with clinical outcomes. Methods: This analysis included patients eligible for CRT and discharged alive between January 2005 and December 2012 from 388 hospitals in Get With The Guidelines‐HF. Participants were linked with Centers for Medicare and Medicaid Services data to evaluate outcomes of all‐cause mortality and HF re‐hospitalization based on CRT status (present on admission, placed during hospitalization, and prescribed at discharge; reference = no CRT). Results: Of 15 619 CRT‐eligible HF patients, 2408 (15%) had CRT on admission, 1269 (8%) underwent CRT implantation during hospitalization and 643 (4%) had CRT prescribed at discharge. Compared with patients without CRT, mortality was lower in those who received CRT implantation during HF hospitalization (adjusted hazard ratio [HR] 0.63; P < 0.0001) and those prescribed CRT at discharge (adjusted HR 0.78; P = 0.048). A reduction in HF re‐hospitalization was observed in patients with CRT implanted during hospitalization (adjusted HR 0.64; P < 0.0001), but not in those who were prescribed CRT at discharge (adjusted HR 1.02; P = 0.77). Conclusion: CRT implantation during HF hospitalization was associated with lower rates of mortality and HF re‐hospitalization. These data suggest that a CRT utilization strategy that does not delay implantation to the post‐discharge period may be appropriate. Randomized data are needed to definitively identify optimal timing of CRT implantation. … (more)
- Is Part Of:
- Clinical cardiology. Volume 42:Issue 2(2019)
- Journal:
- Clinical cardiology
- Issue:
- Volume 42:Issue 2(2019)
- Issue Display:
- Volume 42, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 2
- Issue Sort Value:
- 2019-0042-0002-0000
- Page Start:
- 256
- Page End:
- 263
- Publication Date:
- 2018-12-26
- Subjects:
- cardiac resynchronization therapy -- CRT -- heart failure -- mortality -- outcomes -- re‐hospitalization
Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.23135 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9523.xml