Experimental evaluation of seven quality control phantoms for digital breast tomosynthesis. (January 2019)
- Record Type:
- Journal Article
- Title:
- Experimental evaluation of seven quality control phantoms for digital breast tomosynthesis. (January 2019)
- Main Title:
- Experimental evaluation of seven quality control phantoms for digital breast tomosynthesis
- Authors:
- Sage, Julie
Fezzani, Karen L.
Fitton, Isabelle
Hadid, Lama
Moussier, Aurélie
Pierrat, Noëlle
Martineau, Antoine
Dreuil, Serge
Heulers, Loïc
Etard, Cécile - Abstract:
- Highlights: Visual image score analysis is recommended to check the whole DBT chain quality. ACR, TOMOMAM®, TOMOPHAN® appeared to be pertinent for evaluation of DBT image score. Phantom's manufacturers should collaborate with DBT system's manufacturers. Abstract: Purposes: The introduction of digital breast tomosynthesis (DBT) into the French breast cancer screening program is forecast by the authorities. The aim of the present study was to evaluate image quality phantoms to be used as internal quality controls. Methods: Seven breast phantoms dedicated to quality control in mammography were evaluated on reconstructed DBT images: ACR Model 015, BR3D, DBT QC model 021, Mam/Digi-EPQC, MTM100, TOMOMAM® and TOMOPHAN®. Two representative image parameters of DBT images were studied: image score and z-resolution, when inserts were included in the phantom, on five DBT systems of three different brands. Three observers were involved. Results: The MTM100, Mam/Digi-EPQC, BR3D, DBT QC model 021 phantoms' images presented artefacts affecting the image score. The ACR Model 015, TOMOMAM® and TOMOPHAN® phantoms appeared to be pertinent for DBT image score analysis. Due to saturation artefacts, Z-resolution results were not coherent with the theory for all phantoms except by using aluminium beads in the TOMOMAM® phantom. Conclusions: Phantom manufacturers should be encouraged to collaborate with DBT system manufacturers in order to design universal phantoms suitable for all systems for moreHighlights: Visual image score analysis is recommended to check the whole DBT chain quality. ACR, TOMOMAM®, TOMOPHAN® appeared to be pertinent for evaluation of DBT image score. Phantom's manufacturers should collaborate with DBT system's manufacturers. Abstract: Purposes: The introduction of digital breast tomosynthesis (DBT) into the French breast cancer screening program is forecast by the authorities. The aim of the present study was to evaluate image quality phantoms to be used as internal quality controls. Methods: Seven breast phantoms dedicated to quality control in mammography were evaluated on reconstructed DBT images: ACR Model 015, BR3D, DBT QC model 021, Mam/Digi-EPQC, MTM100, TOMOMAM® and TOMOPHAN®. Two representative image parameters of DBT images were studied: image score and z-resolution, when inserts were included in the phantom, on five DBT systems of three different brands. Three observers were involved. Results: The MTM100, Mam/Digi-EPQC, BR3D, DBT QC model 021 phantoms' images presented artefacts affecting the image score. The ACR Model 015, TOMOMAM® and TOMOPHAN® phantoms appeared to be pertinent for DBT image score analysis. Due to saturation artefacts, Z-resolution results were not coherent with the theory for all phantoms except by using aluminium beads in the TOMOMAM® phantom. Conclusions: Phantom manufacturers should be encouraged to collaborate with DBT system manufacturers in order to design universal phantoms suitable for all systems for more complete quality control. From our study we can propose several specifications for an ideal and universal phantom designed for internal quality control in DBT. Phantoms should allow sensitive image score measurements. The background structure should be realistic to avoid artefacts. Phantoms should have a standard breast-like shape and size. … (more)
- Is Part Of:
- Physica medica. Volume 57(2019)
- Journal:
- Physica medica
- Issue:
- Volume 57(2019)
- Issue Display:
- Volume 57, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 57
- Issue:
- 2019
- Issue Sort Value:
- 2019-0057-2019-0000
- Page Start:
- 137
- Page End:
- 144
- Publication Date:
- 2019-01
- Subjects:
- ASF artefact spread function -- DBT digital breast tomosynthesis -- EUREF European Reference Organisation for Quality Assured Breast Screening and Diagnostic Services -- FWHM full width at half-maximum -- GEHC general electric health care -- SSP slice sensitivity profile
Breast -- Diagnostic imaging -- Digital breast tomosynthesis -- Quality control -- Screening
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.12.031 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9503.xml