3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT). (January 2019)
- Record Type:
- Journal Article
- Title:
- 3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT). (January 2019)
- Main Title:
- 3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)
- Authors:
- Alhamada, Husein
Simon, Stephane
Philippson, Catherine
Vandekerkhove, Christophe
Jourani, Younes
Pauly, Nicolas
VanGestel, Dirk
Reynaert, Nick - Abstract:
- Highlights: Modeling intraoperative electron therapy (IOERT) machine by using Monte Carlo. A surgical simulation and navigation of IOERT operation was simulated. Feasibility to move from manual dosimetry of IOERT to 3D dosimetry was presented. Abstract: Purpose: This paper studies the feasibility of using Monte Carlo (MC) for treatment planning of intraoperative electron radiation therapy (IOERT) procedure to get 3D dose by using patient's CT images. Methods: The IOERT treatment planning was performed using the following successive steps: I) The Mobetron 1000® machine was modelled with the EGSnrc MC codes. II) The MC model was validated with measurements of percentage depth doses and profiles for three energies (12, 9, 6) MeV. III) CT images were imported as DICOM files. IV) Contouring of the planning target volume (PTV) and the organs at risk was done by the radiation oncologist. V) The medical physicist with the radiation oncologist, had chosen the same parameters of IOERT procedures like energy, applicator (type, size) and using or not bolus. VI) Finally, dose calculation and analysis of 3D maps was carried out. Results: The tuning process of the MC model provides good results, as the maximum value of the root mean square deviation (RMSD) was less than 3% between the MC simulated PDDs and the measured PDDs. The contouring and dose analysis review were easy to conduct for the classical treatment planning system. The radiation oncologist had many tools for dose analysisHighlights: Modeling intraoperative electron therapy (IOERT) machine by using Monte Carlo. A surgical simulation and navigation of IOERT operation was simulated. Feasibility to move from manual dosimetry of IOERT to 3D dosimetry was presented. Abstract: Purpose: This paper studies the feasibility of using Monte Carlo (MC) for treatment planning of intraoperative electron radiation therapy (IOERT) procedure to get 3D dose by using patient's CT images. Methods: The IOERT treatment planning was performed using the following successive steps: I) The Mobetron 1000® machine was modelled with the EGSnrc MC codes. II) The MC model was validated with measurements of percentage depth doses and profiles for three energies (12, 9, 6) MeV. III) CT images were imported as DICOM files. IV) Contouring of the planning target volume (PTV) and the organs at risk was done by the radiation oncologist. V) The medical physicist with the radiation oncologist, had chosen the same parameters of IOERT procedures like energy, applicator (type, size) and using or not bolus. VI) Finally, dose calculation and analysis of 3D maps was carried out. Results: The tuning process of the MC model provides good results, as the maximum value of the root mean square deviation (RMSD) was less than 3% between the MC simulated PDDs and the measured PDDs. The contouring and dose analysis review were easy to conduct for the classical treatment planning system. The radiation oncologist had many tools for dose analysis such as DVH and color wash for all the slides. Summation of the 3D dose of IOERT with other radiotherapy plans is possible and helpful for total dose estimation. Archiving and documentation is as good as treatment planning system (TPS). Conclusions: The method displayed in this paper provides a step forward for IOERT Dosimetry and allows to obtain accurate dosimetry of treated volumes. … (more)
- Is Part Of:
- Physica medica. Volume 57(2019)
- Journal:
- Physica medica
- Issue:
- Volume 57(2019)
- Issue Display:
- Volume 57, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 57
- Issue:
- 2019
- Issue Sort Value:
- 2019-0057-2019-0000
- Page Start:
- 207
- Page End:
- 214
- Publication Date:
- 2019-01
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.12.037 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9503.xml