Agreement between digital breast tomosynthesis and pathologic tumour size for staging breast cancer, and comparison with standard mammography. (February 2019)
- Record Type:
- Journal Article
- Title:
- Agreement between digital breast tomosynthesis and pathologic tumour size for staging breast cancer, and comparison with standard mammography. (February 2019)
- Main Title:
- Agreement between digital breast tomosynthesis and pathologic tumour size for staging breast cancer, and comparison with standard mammography
- Authors:
- Marinovich, M. Luke
Bernardi, Daniela
Macaskill, Petra
Ventriglia, Anna
Sabatino, Vincenzo
Houssami, Nehmat - Abstract:
- Abstract: Purpose: Tomosynthesis is proposed to improve breast cancer assessment and staging. We compared tomosynthesis and mammography in estimating the size of newly-diagnosed breast cancers. Methods: All pathologically-confirmed cancers detected in the STORM-2 trial (90 cancers, 85 women) were retrospectively measured on tomosynthesis by two independent readers. One reader also measured cancers on mammography. Relative mean differences (MDs) and 95% limits of agreement (LOA) with pathology were estimated for tomosynthesis and mammography within a single reader (Analysis 1) and between two readers (Analysis 2). Results: Where cancers were detected and hence measured by both tests, tomosynthesis overestimated pathologic size relative to mammography (Analysis 1: MD 5% versus 1%, Analysis 2: 7% versus 3%; P = 0.10 both analyses). There was similar, large measurement variability for both tests (LOA range: −60% to +166%). Overestimation by tomosynthesis was attributable to the subgroup with dense breasts (MDs = 12–13% versus 4% for mammography). There was low average bias for both tests in the low-density subgroup (MDs = 0–4%). LOA were larger in dense breasts for both tomosynthesis and mammography ( P ≤ 0.02 all comparisons). Cancers detected only by tomosynthesis were more frequently in dense breasts (60–68%): for those tumours size was estimated with increased measurement variability (LOA ranging from −75% to +293%). Conclusions: On average, tomosynthesis overestimatesAbstract: Purpose: Tomosynthesis is proposed to improve breast cancer assessment and staging. We compared tomosynthesis and mammography in estimating the size of newly-diagnosed breast cancers. Methods: All pathologically-confirmed cancers detected in the STORM-2 trial (90 cancers, 85 women) were retrospectively measured on tomosynthesis by two independent readers. One reader also measured cancers on mammography. Relative mean differences (MDs) and 95% limits of agreement (LOA) with pathology were estimated for tomosynthesis and mammography within a single reader (Analysis 1) and between two readers (Analysis 2). Results: Where cancers were detected and hence measured by both tests, tomosynthesis overestimated pathologic size relative to mammography (Analysis 1: MD 5% versus 1%, Analysis 2: 7% versus 3%; P = 0.10 both analyses). There was similar, large measurement variability for both tests (LOA range: −60% to +166%). Overestimation by tomosynthesis was attributable to the subgroup with dense breasts (MDs = 12–13% versus 4% for mammography). There was low average bias for both tests in the low-density subgroup (MDs = 0–4%). LOA were larger in dense breasts for both tomosynthesis and mammography ( P ≤ 0.02 all comparisons). Cancers detected only by tomosynthesis were more frequently in dense breasts (60–68%): for those tumours size was estimated with increased measurement variability (LOA ranging from −75% to +293%). Conclusions: On average, tomosynthesis overestimates pathologic tumour size in women with dense breasts; that difference is more likely to impact management in women with larger tumours. The main advantage of tomosynthesis appears to be detecting mammographically-occult cancers; however tomosynthesis less accurately measured those cancers in dense breasts (large measurement variability). Highlights: Tumour size was overestimated by tomosynthesis relative to mammography. Overestimation was attributable to the subgroup with high breast density. There was low average bias for both tests in the low-density subgroup. Cancers detected only by tomosynthesis were measured with large variability. … (more)
- Is Part Of:
- Breast. Volume 43(2019)
- Journal:
- Breast
- Issue:
- Volume 43(2019)
- Issue Display:
- Volume 43, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 43
- Issue:
- 2019
- Issue Sort Value:
- 2019-0043-2019-0000
- Page Start:
- 59
- Page End:
- 66
- Publication Date:
- 2019-02
- Subjects:
- Tomosynthesis -- Mammography -- Breast cancer -- Staging -- Tumour size -- Accuracy
Breast -- Diseases -- Periodicals
Breast -- Tumors -- Periodicals
Breast -- Periodicals
Electronic journals
Periodicals
616 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09609776 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0960-9776;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/brst/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09609776 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09609776 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.breast.2018.11.001 ↗
- Languages:
- English
- ISSNs:
- 0960-9776
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2277.492700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9512.xml