A new visible-light-excitable ICT-CHEF-mediated fluorescence 'turn-on' probe for the selective detection of Cd2+ in a mixed aqueous system with live-cell imaging. Issue 12 (25th February 2015)
- Record Type:
- Journal Article
- Title:
- A new visible-light-excitable ICT-CHEF-mediated fluorescence 'turn-on' probe for the selective detection of Cd2+ in a mixed aqueous system with live-cell imaging. Issue 12 (25th February 2015)
- Main Title:
- A new visible-light-excitable ICT-CHEF-mediated fluorescence 'turn-on' probe for the selective detection of Cd2+ in a mixed aqueous system with live-cell imaging
- Authors:
- Goswami, Shyamaprosad
Aich, Krishnendu
Das, Sangita
Das Mukhopadhyay, Chitrangada
Sarkar, Deblina
Mondal, Tapan Kumar - Abstract:
- Abstract : A new quinoline based sensor was developed and applied for the selective detection of Cd 2+ both in vitro and in vivo . Abstract : A new quinoline based sensor was developed and applied for the selective detection of Cd 2+ both in vitro and in vivo . The designed probe displays a straightforward approach for the selective detection of Cd 2+ with a prominent fluorescence enhancement along with a large red shift (∼38 nm), which may be because of the CHEF (chelation-enhanced fluorescence) and ICT (internal charge transfer) processes after interaction with Cd 2+ . The interference from other biologically important competing metal ions, particularly Zn 2+, has not been observed. The visible-light excitability of the probe merits in the viewpoint of its biological application. The probe enables the detection of intracellular Cd 2+ with non-cytotoxic effects, which was demonstrated with the live RAW cells. The experimentally observed change in the structure and electronic properties of the sensor after the addition of Cd 2+ were modelled by the density functional theory (DFT) and time-dependent density functional theory (TDDFT) computational calculations, respectively. Moreover, the test strip experiment with this sensor exhibits both absorption and fluorescence color changes when exposed to Cd 2+ in a mixed aqueous solution, which also makes the probe more useful. The minimum limit of detection of Cd 2+ by the probe was in the range of 9.9 × 10 −8 M level.
- Is Part Of:
- Dalton transactions. Volume 44:Issue 12(2015)
- Journal:
- Dalton transactions
- Issue:
- Volume 44:Issue 12(2015)
- Issue Display:
- Volume 44, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 44
- Issue:
- 12
- Issue Sort Value:
- 2015-0044-0012-0000
- Page Start:
- 5763
- Page End:
- 5770
- Publication Date:
- 2015-02-25
- Subjects:
- Chemistry, Inorganic -- Periodicals
Chemistry, Physical and theoretical -- Periodicals
Chemistry, Inorganic -- Periodicals
546.05 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/dt#!issueid=dt043040&type=current&issnprint=1477-9226 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c4dt02463j ↗
- Languages:
- English
- ISSNs:
- 1477-9226
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3517.830000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9481.xml