Restoring prolonged standing via functional electrical stimulation after spinal cord injury: A systematic review of control strategies. (March 2019)
- Record Type:
- Journal Article
- Title:
- Restoring prolonged standing via functional electrical stimulation after spinal cord injury: A systematic review of control strategies. (March 2019)
- Main Title:
- Restoring prolonged standing via functional electrical stimulation after spinal cord injury: A systematic review of control strategies
- Authors:
- Ibitoye, Morufu Olusola
Hamzaid, Nur Azah
Hayashibe, Mitsuhiro
Hasnan, Nazirah
Davis, Glen M. - Abstract:
- Abstract: Background: Functional Electrical Stimulation (FES) technologies can facilitate standing in persons with spinal cord injury (SCI), and prolonged standing elicited via FES may offer both functional and therapeutic benefits to users. However, the current attainable FES-evoked standing duration is typically short and below the threshold for clinical efficacy. To promote the objective selection of suitable control strategies to restore prolonged and higher-quality standing duration, this study summarised current and emerging approaches to FES standing. Method: PubMed, IEEE Xplore, Web of Science and Google Scholar databases were searched for relevant studies on FES-evoked standing after SCI between the earliest return date and December 2017. Thereafter, the quality of all included studies was objectively evaluated using the Downs and Black methodological assessment checklist. Results: Twenty-five full-length articles, with mean methodological quality score of 56%, met the inclusion criteria and were retained for analysis. Recent advancements to promote prolonged standing relied greatly on the use of voluntary upper extremities for balancing with arm engaged or disengaged. Some widely-reported constraints were issues of unpredictable postural sway, and unusual muscle responses and perturbations, such as spasm or spasticity, which diminished the reliability of the standing control sensors and algorithms. Conclusion: Closed-loop control of FES-supported standing withAbstract: Background: Functional Electrical Stimulation (FES) technologies can facilitate standing in persons with spinal cord injury (SCI), and prolonged standing elicited via FES may offer both functional and therapeutic benefits to users. However, the current attainable FES-evoked standing duration is typically short and below the threshold for clinical efficacy. To promote the objective selection of suitable control strategies to restore prolonged and higher-quality standing duration, this study summarised current and emerging approaches to FES standing. Method: PubMed, IEEE Xplore, Web of Science and Google Scholar databases were searched for relevant studies on FES-evoked standing after SCI between the earliest return date and December 2017. Thereafter, the quality of all included studies was objectively evaluated using the Downs and Black methodological assessment checklist. Results: Twenty-five full-length articles, with mean methodological quality score of 56%, met the inclusion criteria and were retained for analysis. Recent advancements to promote prolonged standing relied greatly on the use of voluntary upper extremities for balancing with arm engaged or disengaged. Some widely-reported constraints were issues of unpredictable postural sway, and unusual muscle responses and perturbations, such as spasm or spasticity, which diminished the reliability of the standing control sensors and algorithms. Conclusion: Closed-loop control of FES-supported standing with arms-free modality and voluntary upper extremity balancing promoted the "longest" standing duration and "highest" efficacy among the reported methods, albeit with a limited successful transfer of the technology into the routine clinical practice or community deployment. However, open-loop control of FES standing appeared popular, particularly for its therapeutic gains, simplicity of use and other health and psychological benefits associated with weight bearing through the legs. The information from this study could stimulate useful knowledge that may promote clinically significant FES-supported standing duration. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 49(2019)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 49(2019)
- Issue Display:
- Volume 49, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 49
- Issue:
- 2019
- Issue Sort Value:
- 2019-0049-2019-0000
- Page Start:
- 34
- Page End:
- 47
- Publication Date:
- 2019-03
- Subjects:
- Functional electrical stimulation -- Standing -- Spinal cord injury and control sensors
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2018.11.006 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9475.xml