Combinations of gait speed testing protocols (automatic vs manual timer, dynamic vs static start) can significantly influence the prevalence of slowness: Results from the Korean Frailty and Aging Cohort Study. (March 2019)
- Record Type:
- Journal Article
- Title:
- Combinations of gait speed testing protocols (automatic vs manual timer, dynamic vs static start) can significantly influence the prevalence of slowness: Results from the Korean Frailty and Aging Cohort Study. (March 2019)
- Main Title:
- Combinations of gait speed testing protocols (automatic vs manual timer, dynamic vs static start) can significantly influence the prevalence of slowness: Results from the Korean Frailty and Aging Cohort Study
- Authors:
- Kim, Miji
Won, Chang Won - Abstract:
- Highlights: The manual timer systematically underestimated usual gait speed in community settings. The static start protocol showed a higher prevalence of slowness than the dynamic start protocol. The automatic timer may be useful for measuring gait speed in healthy older adults. Abstract: Aim: This study aimed to compare 4-m usual gait speed obtained with different protocols and to determine the prevalence of slowness using different diagnostic criteria in a large cohort of community-dwelling older adults. Methods: A total of 1177 non-disabled community-dwelling older adults aged 70–84 years were assessed for 4-m usual gait speed using four different testing protocols: (1) automatic timer (ultrasonic sensor), dynamic start; (2) manual timer (stopwatch), dynamic start; (3) automatic timer, static start; and (4) manual timer, static start. To assess agreement between usual gait speed and the testing protocols, linear regression and Bland-Altman analyses were performed. Results: There was systematic bias (i.e., difference between automatic timer and manual timer methods), with underestimation of usual gait speed (bias 0.0695 m/s for dynamic start; bias 0.0702 m/s for static start) by the manual timer. There was systematic bias in start conditions, with underestimation of usual gait speed with a static start using both timer methods, compared with that in dynamic start assessment (P < 0.001). The prevalence of slowness ranged from 2.3 to 4.7% in men and 5.9–11.1% in women forHighlights: The manual timer systematically underestimated usual gait speed in community settings. The static start protocol showed a higher prevalence of slowness than the dynamic start protocol. The automatic timer may be useful for measuring gait speed in healthy older adults. Abstract: Aim: This study aimed to compare 4-m usual gait speed obtained with different protocols and to determine the prevalence of slowness using different diagnostic criteria in a large cohort of community-dwelling older adults. Methods: A total of 1177 non-disabled community-dwelling older adults aged 70–84 years were assessed for 4-m usual gait speed using four different testing protocols: (1) automatic timer (ultrasonic sensor), dynamic start; (2) manual timer (stopwatch), dynamic start; (3) automatic timer, static start; and (4) manual timer, static start. To assess agreement between usual gait speed and the testing protocols, linear regression and Bland-Altman analyses were performed. Results: There was systematic bias (i.e., difference between automatic timer and manual timer methods), with underestimation of usual gait speed (bias 0.0695 m/s for dynamic start; bias 0.0702 m/s for static start) by the manual timer. There was systematic bias in start conditions, with underestimation of usual gait speed with a static start using both timer methods, compared with that in dynamic start assessment (P < 0.001). The prevalence of slowness ranged from 2.3 to 4.7% in men and 5.9–11.1% in women for <0.80 m/s, and from 17.1 to 30.5% in men and 26.3–45.9% in women for <1.00 m/s. Conclusions: The findings of this study indicated that 4-m usual gait speed measured under different testing protocols was able to determine different prevalence rates of slowness among non-disabled community-dwelling older adults. An automatic timer may be useful for measuring gait speed changes in individuals likely to have faster gait speed in community-based research settings. … (more)
- Is Part Of:
- Archives of gerontology and geriatrics. Volume 81(2019)
- Journal:
- Archives of gerontology and geriatrics
- Issue:
- Volume 81(2019)
- Issue Display:
- Volume 81, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 2019
- Issue Sort Value:
- 2019-0081-2019-0000
- Page Start:
- 215
- Page End:
- 221
- Publication Date:
- 2019-03
- Subjects:
- Aging -- Gait speed -- Mobility -- Slowness -- Testing protocol
Aging -- Periodicals
Geriatrics -- Periodicals
Gerontology -- Periodicals
Electronic journals
305.26 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01674943 ↗
http://www.elsevier.com/wps/find/journaldescription.cws%5Fhome/506044/description#description ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01674943 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01674943 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.archger.2018.12.009 ↗
- Languages:
- English
- ISSNs:
- 0167-4943
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1634.401000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9459.xml