229. Breast Imaging Quality: Conventional Handheld Ultrasound versus Automated 3D Breast Ultrasound System. (December 2018)
- Record Type:
- Journal Article
- Title:
- 229. Breast Imaging Quality: Conventional Handheld Ultrasound versus Automated 3D Breast Ultrasound System. (December 2018)
- Main Title:
- 229. Breast Imaging Quality: Conventional Handheld Ultrasound versus Automated 3D Breast Ultrasound System
- Authors:
- Levrero, F.
Vaccara, E.M.L.
Guidasci, G. Rambaldi
Calabrese, M.
Dordolo, M.
Tagliafico, A.
Gristina, L.
Schiaffino, S.
Massone, A.M.
Piana, M. - Abstract:
- Abstract : Purpose: Automated 3D Breast Ultrasound (ABUS) as an adjunct to mammography is promising technology in screening especially in women with dense breast parenchyma. We aim to inquire numerically imaging performance of Invenia ABUS (GE Healthcare, WI, USA) in comparison to conventional handheld Ultrasound (US), just to check their similar malignancy detection rates[1] . Methods: According to SIRM ( Società Italiana di Radiologia Medica [2] ), using a certified phantom it's possible to provide a general judgment on the operation of the equipment. So we used a rubber-based tissue mimicking material shown in the figure, UC-551M (ATS Laboratories). This phantom allows to investigate every kind of parameters (line targets, axial and lateral resolution, anechoic targets structures of different sizes and gray scale target structures). The phantom acquisitions were made in clinical mode: ABUS select automatically depth of penetration 3, 5/4/5 cm and frequency 10/9/8, 18 MHz depending on the size of the breast (small/medium/large); conventional US depth has been optimized in the range 4–5 cm and 7, 5–15 MHz by an experienced radiologist depending on the specific insert to display, as suggested by ATS Laboratory[3] . Results: The preliminary results are shown in the table. Displayed dynamic range is optimal for all the ultrasound scanners (coefficient of determination R 2 ⩾95%) and the maximum value is ABUS and Samsung score of 99%. Distance measures are coherent, there is noAbstract : Purpose: Automated 3D Breast Ultrasound (ABUS) as an adjunct to mammography is promising technology in screening especially in women with dense breast parenchyma. We aim to inquire numerically imaging performance of Invenia ABUS (GE Healthcare, WI, USA) in comparison to conventional handheld Ultrasound (US), just to check their similar malignancy detection rates[1] . Methods: According to SIRM ( Società Italiana di Radiologia Medica [2] ), using a certified phantom it's possible to provide a general judgment on the operation of the equipment. So we used a rubber-based tissue mimicking material shown in the figure, UC-551M (ATS Laboratories). This phantom allows to investigate every kind of parameters (line targets, axial and lateral resolution, anechoic targets structures of different sizes and gray scale target structures). The phantom acquisitions were made in clinical mode: ABUS select automatically depth of penetration 3, 5/4/5 cm and frequency 10/9/8, 18 MHz depending on the size of the breast (small/medium/large); conventional US depth has been optimized in the range 4–5 cm and 7, 5–15 MHz by an experienced radiologist depending on the specific insert to display, as suggested by ATS Laboratory[3] . Results: The preliminary results are shown in the table. Displayed dynamic range is optimal for all the ultrasound scanners (coefficient of determination R 2 ⩾95%) and the maximum value is ABUS and Samsung score of 99%. Distance measures are coherent, there is no geometric distortion. The analysis of the Point Spread Function is underway with advanced mathematical methods. Conclusions: ABUS provides a 3D volume consisting of 330 trans-axial images, whose quality is generally comparable with US 2D images. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 203
- Page End:
- 204
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.240 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9461.xml