247. From CTDI-in-air to equilibrium dose. (December 2018)
- Record Type:
- Journal Article
- Title:
- 247. From CTDI-in-air to equilibrium dose. (December 2018)
- Main Title:
- 247. From CTDI-in-air to equilibrium dose
- Authors:
- Spampinato, S.
Gueli, A.
Raffaele, L. - Abstract:
- Abstract : Purpose: CTDI metric is currently used for standardized measures of dose-output. Recently, however, strengths/weaknesses of CTDI have been debated: (1) 100 mm-long ionization chambers may not be sufficiently long to measure the tails of scattered dose distribution, (2) phantoms used are shorter than an adult torso. Two approaches have been proposed: use longer ionization chambers and phantoms, or using small probes to determine the equilibrium dose ( D eq ) [1] . The present study proposes a method based on CTDI-in-air metric to calculate D eq following the approach suggested by Li et al.[2] . The method was also validated using radiochromic films. Methods: First, P H and P B parameters were evaluated for the conversion of weighted-CTDI (CTDIw) to CTDI-in-air. Measurements were performed with a 100 mm-pencil chamber in standard setup with Head and Body phantoms and in air. Subsequently, D eq was calculated using the values reported by the CT-console and those obtained with CTDI-in-air and P / P H with values suggested by Li et al.. Finally, a method to calculate CTDI-in-air with radiochromic films has been validated. Strips of film were irradiated with the same setup and calibrated using a standard procedure. Dose profiles were extracted and CTDI-in-air calculated and validated with standard measurements. Results: Table 1 shows D eq values obtained for CTDIw and CTDI-in-air. Differences are higher for smaller collimations, not routinely used in clinical practice.Abstract : Purpose: CTDI metric is currently used for standardized measures of dose-output. Recently, however, strengths/weaknesses of CTDI have been debated: (1) 100 mm-long ionization chambers may not be sufficiently long to measure the tails of scattered dose distribution, (2) phantoms used are shorter than an adult torso. Two approaches have been proposed: use longer ionization chambers and phantoms, or using small probes to determine the equilibrium dose ( D eq ) [1] . The present study proposes a method based on CTDI-in-air metric to calculate D eq following the approach suggested by Li et al.[2] . The method was also validated using radiochromic films. Methods: First, P H and P B parameters were evaluated for the conversion of weighted-CTDI (CTDIw) to CTDI-in-air. Measurements were performed with a 100 mm-pencil chamber in standard setup with Head and Body phantoms and in air. Subsequently, D eq was calculated using the values reported by the CT-console and those obtained with CTDI-in-air and P / P H with values suggested by Li et al.. Finally, a method to calculate CTDI-in-air with radiochromic films has been validated. Strips of film were irradiated with the same setup and calibrated using a standard procedure. Dose profiles were extracted and CTDI-in-air calculated and validated with standard measurements. Results: Table 1 shows D eq values obtained for CTDIw and CTDI-in-air. Differences are higher for smaller collimations, not routinely used in clinical practice. For radiochromic film the maximum difference compared to standard measurements is 10%, but the average error is about 7% for a voltage of 120 kV and 2% for 140 kV. Conclusions: CTDI-in-air can be measured quickly and could be helpful in calculating Deq. Radiochromic films allow measuring CTDI-in-air for standard and wider collimations (i.e. ConeBeam-CT). … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 214
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.258 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9460.xml