232. Implementation of an edited-PRESS sequence for the detection of the 2-Hydroxyglutarate metabolite. (December 2018)
- Record Type:
- Journal Article
- Title:
- 232. Implementation of an edited-PRESS sequence for the detection of the 2-Hydroxyglutarate metabolite. (December 2018)
- Main Title:
- 232. Implementation of an edited-PRESS sequence for the detection of the 2-Hydroxyglutarate metabolite
- Authors:
- Savini, A.
Bianchini, D.
Belli, M.L.
Mezzenga, E.
Feliciani, G.
Ravaglia, V.
Falaschi, D.
Barone, D.
Cenni, P.
Sarnelli, A. - Abstract:
- Abstract : Purpose: The 2-Hydroxyglutarate (2-HG) metabolite can be quantified with MR-spectroscopy using an edited-PRESS sequence with shifted echo times. This metabolite has a key role in staging low-grade gliomas. The aim of this work was to implement the edited-PRESS for the detection of the 2-HG within our MR-scanner. Furthermore, we studied several sequence parameters in order to optimize the spectrum signal-to-noise-ratio (SNR), while limiting the acquisition time. Methods: A homemade phantom containing a solution of choline (2 mM) and creatine (6 mM) was built to simulate the healthy brain tissue. A Philips Ingenia-3T scanner was used in service-mode to generate single-voxel MR-spectra using the edited-PRESS. The dependence of the SNR with the number of signal acquisitions (NSA) and the voxel volume was characterized. Furthermore, the impact of two shimming algorithms (automatic and semi-automatic) was studied. The LCModel software was used to fit the acquired spectra. The root-mean-square (RMS) between measured and fitted spectra was employed to evaluate the fit quality. Results: The SNR showed a linear correlation (R2 = 0.99) with the quantity [NSÂ(1/2) × Voxel Volume], which is consistent with the theoretical behaviour. In terms of spectrum SNR, a not significant difference (p = 0.38, paired t-test) was found between the shimming algorithms (Fig. 1). The fit RMS was inversely proportional (R2 = 0.99) to the quantity [NSÂ(1/2) × Voxel Volume]. A simple formula wasAbstract : Purpose: The 2-Hydroxyglutarate (2-HG) metabolite can be quantified with MR-spectroscopy using an edited-PRESS sequence with shifted echo times. This metabolite has a key role in staging low-grade gliomas. The aim of this work was to implement the edited-PRESS for the detection of the 2-HG within our MR-scanner. Furthermore, we studied several sequence parameters in order to optimize the spectrum signal-to-noise-ratio (SNR), while limiting the acquisition time. Methods: A homemade phantom containing a solution of choline (2 mM) and creatine (6 mM) was built to simulate the healthy brain tissue. A Philips Ingenia-3T scanner was used in service-mode to generate single-voxel MR-spectra using the edited-PRESS. The dependence of the SNR with the number of signal acquisitions (NSA) and the voxel volume was characterized. Furthermore, the impact of two shimming algorithms (automatic and semi-automatic) was studied. The LCModel software was used to fit the acquired spectra. The root-mean-square (RMS) between measured and fitted spectra was employed to evaluate the fit quality. Results: The SNR showed a linear correlation (R2 = 0.99) with the quantity [NSÂ(1/2) × Voxel Volume], which is consistent with the theoretical behaviour. In terms of spectrum SNR, a not significant difference (p = 0.38, paired t-test) was found between the shimming algorithms (Fig. 1). The fit RMS was inversely proportional (R2 = 0.99) to the quantity [NSÂ(1/2) × Voxel Volume]. A simple formula was derived from these results in order to calculate the optimum NSA, once the voxel volume has been fixed. Conclusions: The implemented PRESS generated MR-spectra whose SNR dependence was compatible with the theoretical behavior. Since the semi-automatic shimming algorithm did not improve the spectrum SNR significantly, the automatic modality is suggested. The developed formula can be used by the MR-technologists to rapidly determine the optimum NSA of the edited-PRESS, once the voxel volume has been fixed (Table 1 ). … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 206
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.243 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9460.xml