Tarducci, R. - Abstract:
- Abstract: Purpose: Hippocampal avoidance during irradiation is hypothesized to reduce the risk of memory function decline. This study is designed to evaluate the dosimetric and clinical results of Helical Tomotherapy (HT) whole brain radiotherapy with hippocampal avoidance (WBHA) and Simultaneous Integrated Boost (SIB). Methods: A total of 19 patients with 1 to 4 brain metastases (BM), diameter ⩽3 cm, absent or controlled extracranial disease were planned for WBHA with SIB using HT, from September 2014 to November 2017. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been registered with the planning CT image set. The hippocampal Planning Risk Volume was generated using a 5 mm uniform margin around the hippocampi. The BM were contoured on T1-weighted MRI registered with the planning computed tomography (CT), and the BM-PTV was the BM expanded 3 mm in all directions. The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume, expanded 3 mm in all directions, minus hippocampal PRV and BM-PTVs. HT plans were generated with the following parameters: field width set at 1.05 cm, pitch 0.287, modulation factor (MF) set in the range 2–3 leading to a final value of 2 on average (range 1.3–2.8). Prescription dose was 30 Gy for WB-PTV and 40 Gy for each BM-PTVs in 10 fractions. Results: Dosimetric result were reported in Table 1: all the parameter analysed were very promising and in accord to the RTOGAbstract: Purpose: Hippocampal avoidance during irradiation is hypothesized to reduce the risk of memory function decline. This study is designed to evaluate the dosimetric and clinical results of Helical Tomotherapy (HT) whole brain radiotherapy with hippocampal avoidance (WBHA) and Simultaneous Integrated Boost (SIB). Methods: A total of 19 patients with 1 to 4 brain metastases (BM), diameter ⩽3 cm, absent or controlled extracranial disease were planned for WBHA with SIB using HT, from September 2014 to November 2017. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been registered with the planning CT image set. The hippocampal Planning Risk Volume was generated using a 5 mm uniform margin around the hippocampi. The BM were contoured on T1-weighted MRI registered with the planning computed tomography (CT), and the BM-PTV was the BM expanded 3 mm in all directions. The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume, expanded 3 mm in all directions, minus hippocampal PRV and BM-PTVs. HT plans were generated with the following parameters: field width set at 1.05 cm, pitch 0.287, modulation factor (MF) set in the range 2–3 leading to a final value of 2 on average (range 1.3–2.8). Prescription dose was 30 Gy for WB-PTV and 40 Gy for each BM-PTVs in 10 fractions. Results: Dosimetric result were reported in Table 1: all the parameter analysed were very promising and in accord to the RTOG 0933 trial[1] . The mean treatment time was 8.7 min (range 6.5–12.6 min). Conclusions: HT plans achieved three objectives: quite homogeneous whole brain dose distribution; conformal hippocampal avoidance; and high coverage to the BM. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 172
- Page End:
- 173
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.190 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9460.xml