Applicability and repeatability in angiography systems of statistical method for the low contrast detectability. (December 2018)
- Record Type:
- Journal Article
- Title:
- Applicability and repeatability in angiography systems of statistical method for the low contrast detectability. (December 2018)
- Main Title:
- Applicability and repeatability in angiography systems of statistical method for the low contrast detectability
- Authors:
- Milan, L.
Nocera, P.
Strocchi, S.
Paruccini, N.
Novario, R. - Abstract:
- Abstract : Purpose: The aim of this study is to evaluate the applicability and repeatability of the Low Contrast Detectability (LCD) statistical method in angiography systems[1, 2] . Methods: A phantom consisting of a square aluminum target and a 5-step-wedge (0.2–1 mmAl) was built according to Radice et al.[2] . Different acquisition protocols were used (low, normal and high dose fluoroscopy; abdomen and cerebtal fluorography), and measurements were repeated for several thicknesses of PolyMethylMethAcrylate (PMMA). A Matlab software automatically calculates LCD values in terms of Pixel Value (PV) and contrast threshold (Ct); it also converts PV in mmAl (Fig. 1), providing the LCD(mmAl)[2] . The short- and long-term repeatability were evaluated by repeating acquisitions five times for every session and monthly (for six months) respectively. Results: The Coefficients of Variation CV(%) reported in Table 1 are always higher for LCD(mmAl) than for LCD(PV) and LCD(Ct), especially in case of long-term measurements which consequently are not repeatable. This difference is related to unstable conversion from PV to mmAl; indeed, the image noise makes difficult to select the steps of the wedge. To overcome the problem, it would be possible to extend the step-wedge up to 2 mmAl, to introduce the point (0, 0) in the conversion curve and to use only the curves with R2 > 0.8. Conclusions: The LCD statistical method is easy to implement and provides consistent results for LCD(PV) andAbstract : Purpose: The aim of this study is to evaluate the applicability and repeatability of the Low Contrast Detectability (LCD) statistical method in angiography systems[1, 2] . Methods: A phantom consisting of a square aluminum target and a 5-step-wedge (0.2–1 mmAl) was built according to Radice et al.[2] . Different acquisition protocols were used (low, normal and high dose fluoroscopy; abdomen and cerebtal fluorography), and measurements were repeated for several thicknesses of PolyMethylMethAcrylate (PMMA). A Matlab software automatically calculates LCD values in terms of Pixel Value (PV) and contrast threshold (Ct); it also converts PV in mmAl (Fig. 1), providing the LCD(mmAl)[2] . The short- and long-term repeatability were evaluated by repeating acquisitions five times for every session and monthly (for six months) respectively. Results: The Coefficients of Variation CV(%) reported in Table 1 are always higher for LCD(mmAl) than for LCD(PV) and LCD(Ct), especially in case of long-term measurements which consequently are not repeatable. This difference is related to unstable conversion from PV to mmAl; indeed, the image noise makes difficult to select the steps of the wedge. To overcome the problem, it would be possible to extend the step-wedge up to 2 mmAl, to introduce the point (0, 0) in the conversion curve and to use only the curves with R2 > 0.8. Conclusions: The LCD statistical method is easy to implement and provides consistent results for LCD(PV) and LCD(Ct). However, the LCD(mmAl) values seem to be not repeatable because of the instability of PV-mmAl conversion; the suggested solutions can improve the conversion, leading to more robust LCD (mmAl) values. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 240
- Page End:
- 241
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.301 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9460.xml