Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study. Issue 1 (January 2019)
- Record Type:
- Journal Article
- Title:
- Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study. Issue 1 (January 2019)
- Main Title:
- Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study
- Authors:
- Ibaraki, Masanobu
Nakamura, Kazuhiro
Toyoshima, Hideto
Takahashi, Kazuhiro
Matsubara, Keisuke
Umetsu, Atsushi
Pfeuffer, Josef
Kuribayashi, Hideto
Kinoshita, Toshibumi - Abstract:
- Pseudo-continuous arterial spin labeling (pCASL) is a completely non-invasive method of cerebral perfusion measurement. However, cerebral blood flow (CBF) quantification is hampered by arterial transit artifacts characterized by bright vascular signals surrounded by decreased signals in tissue regions, which commonly appear in patients with reduced cerebral perfusion pressure. The spatial coefficient of variation (CoV) of pCASL CBF images has been proposed as an alternative region-of-interest (ROI)-based hemodynamic measure to predict prolonged arterial transit time (ATT). This retrospective study investigates the utility of spatial CoV by comparison with 15 O positron emission tomography (PET). For patients with cerebrovascular steno-occlusive disease ( n = 17), spatial CoV was positively correlated with ATT independently measured by pulsed arterial spin labeling ( r = 0.597, p < 0.001), confirming its role as an ATT-like hemodynamic measure. Comparisons with 15 O PET demonstrated that spatial CoV was positively correlated with vascular mean transit time ( r = 0.587, p < 0.001) and negatively correlated with both resting CBF ( r = −0.541, p = 0.001) and CBF response to hypercapnia ( r = −0.373, p = 0.030). ROI-based spatial CoV calculated from single time-point pCASL can potentially detect subtle perfusion abnormalities in clinical settings.
- Is Part Of:
- Journal of cerebral blood flow & metabolism. Volume 39:Issue 1(2019)
- Journal:
- Journal of cerebral blood flow & metabolism
- Issue:
- Volume 39:Issue 1(2019)
- Issue Display:
- Volume 39, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2019-0039-0001-0000
- Page Start:
- 173
- Page End:
- 181
- Publication Date:
- 2019-01
- Subjects:
- Arterial transit artifact -- arterial transit time -- cerebral blood flow -- pseudo-continuous arterial spin labeling -- spatial coefficient of variation
Cerebral circulation -- Periodicals
Brain -- Metabolism -- Periodicals
Brain -- Blood-vessels -- Periodicals
Cerebrovascular disease -- Periodicals
612.824 - Journal URLs:
- http://jcb.sagepub.com/ ↗
http://136.142.56.160/ovidweb/ovidweb.cgi?T=JS&MODE=ovid&NEWS=N&PAGE=toc&D=ovid%5fovft&AN=00004647-000000000-00000 ↗
http://www.jcbfm.com ↗
http://www.nature.com/jcbfm/index.html ↗
http://www.nature.com/ ↗ - DOI:
- 10.1177/0271678X18781667 ↗
- Languages:
- English
- ISSNs:
- 0271-678X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4955.110000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9449.xml