Quantification of human C1 esterase inhibitor protein using an automated turbidimetric immunoassay. Issue 1 (29th July 2018)
- Record Type:
- Journal Article
- Title:
- Quantification of human C1 esterase inhibitor protein using an automated turbidimetric immunoassay. Issue 1 (29th July 2018)
- Main Title:
- Quantification of human C1 esterase inhibitor protein using an automated turbidimetric immunoassay
- Authors:
- Tange, Clare E.
Kaur, Amrit
Verma, Nisha
Hickey, Alaco
Grigoriadou, Sofia
Scott, Chris
Kiani, Sorena
Steven, Rachael
Ponsford, Mark
El‐Shanawany, Tariq
Jolles, Stephen
Harding, Stephen
Parker, Antony R. - Abstract:
- Abstract: Background: Impaired levels or function of C1 inhibitor (C1‐INH) results in angioedema due to increased bradykinin. It is important to distinguish between angioedema related to C1‐INH deficiency and that caused by other mechanisms, as treatment options are different. In hereditary (HAE) and acquired (AAE) angioedema, C1‐INH concentration is measured to aid patient diagnosis. Here, we describe an automated turbidimetric assay to measure C1‐INH concentration on the Optilite ® analyzer. Methods: Linearity, precision, and interference were established over a range of C1‐INH concentrations. The 95th percentile reference interval was generated from 120 healthy adult donors. To compare the Optilite C1‐INH assay with a predicate assay used in a clinical laboratory, samples sent for C1‐INH investigation were used. The predicate results were provided to allow comparison. Results: The Optilite C1‐INH assay was linear across the measuring range at the standard sample dilution. Intra and interassay variability was <6%. The 95th percentile adult reference interval for the assay was 0.21‐0.38 g/L. There was a strong correlation between the Optilite concentrations and those generated with the predicate assay ( R 2 = 0.94, P < 0.0001, slope y = 0.83 x ). All patients with Type I HAE (n = 24) and AAE (n = 3) tested had concentrations below the measuring range in both assays, while all patients with unspecified angioedema (UAE), not diagnosed with HAE or AAE had values within theAbstract: Background: Impaired levels or function of C1 inhibitor (C1‐INH) results in angioedema due to increased bradykinin. It is important to distinguish between angioedema related to C1‐INH deficiency and that caused by other mechanisms, as treatment options are different. In hereditary (HAE) and acquired (AAE) angioedema, C1‐INH concentration is measured to aid patient diagnosis. Here, we describe an automated turbidimetric assay to measure C1‐INH concentration on the Optilite ® analyzer. Methods: Linearity, precision, and interference were established over a range of C1‐INH concentrations. The 95th percentile reference interval was generated from 120 healthy adult donors. To compare the Optilite C1‐INH assay with a predicate assay used in a clinical laboratory, samples sent for C1‐INH investigation were used. The predicate results were provided to allow comparison. Results: The Optilite C1‐INH assay was linear across the measuring range at the standard sample dilution. Intra and interassay variability was <6%. The 95th percentile adult reference interval for the assay was 0.21‐0.38 g/L. There was a strong correlation between the Optilite concentrations and those generated with the predicate assay ( R 2 = 0.94, P < 0.0001, slope y = 0.83 x ). All patients with Type I HAE (n = 24) and AAE (n = 3) tested had concentrations below the measuring range in both assays, while all patients with unspecified angioedema (UAE), not diagnosed with HAE or AAE had values within the reference range. Conclusion: The Optilite assay allows the automated and precise quantification of C1‐INH concentrations in patient samples. It could therefore be used as a tool to aid the investigation of patients with angioedema. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 33:Issue 1(2019)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 33:Issue 1(2019)
- Issue Display:
- Volume 33, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2019-0033-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-07-29
- Subjects:
- AAE -- angioedema -- C1 inactivator -- C1 inhibitor -- C1‐INH -- complement -- HAE -- Optilite -- turbidimetric
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22627 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9450.xml