A method for improvement of mass resolution and isotope accuracy for laser ablation time‐of‐flight mass spectrometers. (9th October 2018)
- Record Type:
- Journal Article
- Title:
- A method for improvement of mass resolution and isotope accuracy for laser ablation time‐of‐flight mass spectrometers. (9th October 2018)
- Main Title:
- A method for improvement of mass resolution and isotope accuracy for laser ablation time‐of‐flight mass spectrometers
- Authors:
- Wiesendanger, Reto
Tulej, Marek
Grimaudo, Valentine
Cedeño‐López, Alena
Lukmanov, Rustam
Riedo, Andreas
Wurz, Peter - Abstract:
- Abstract: Accumulation of spectra is a common approach for improvement of the signal‐to‐noise ratio (SNR) in mass spectrometry. However, severe degradation of the overall spectrum can occur if some individual mass spectra, affected by peak broadening, are included in the accumulation process. In this contribution, we discuss potential sources and effects of spectral distortions by using examples from mass spectra acquired by our miniature laser ablation/ionisation time‐of‐flight mass spectrometer. We show how recent developments in acquisition systems enable to identify individual spectra subjected to peak broadening and present a filtering method capable of systematic and reproducible exclusion of such spectra from the accumulation process. We show that the method can be used on a wide range of materials and present a detailed case study performed on a trevorite mineral sample. Using this method, improvements of the isotope accuracy of Si, Ni, and Cr by factors between 1.6 and 7.7 were achieved. Finally, we discuss the limitations of the method and provide complementary analysis of other materials in the supplementary documents provided with this contribution. Abstract : A new method for the systematic and reproducible improvement of mass resolution and isotope accuracy for laser ablation time‐of‐flight (TOF) instruments is presented and demonstrated on a trevorite mineral sample. Improvements of the isotope accuracies in the range between 1.6 and 3.8 were readily achieved.
- Is Part Of:
- Journal of chemometrics. Volume 33:Number 1(2019)
- Journal:
- Journal of chemometrics
- Issue:
- Volume 33:Number 1(2019)
- Issue Display:
- Volume 33, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 1
- Issue Sort Value:
- 2019-0033-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-10-09
- Subjects:
- filtering method -- improvement of quantitative performance -- isotope accuracy -- laser ablation and ionisation time‐of‐flight mass spectrometry (LIMS‐TOF) -- mass resolution
Chemistry -- Mathematics -- Periodicals
Chemistry -- Statistical methods -- Periodicals
542.85 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cem.3081 ↗
- Languages:
- English
- ISSNs:
- 0886-9383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4957.380000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9447.xml