Ischemic burden assessment of myocardial perfusion CT, compared with SPECT using semi-quantitative and quantitative approaches. (1st March 2019)
- Record Type:
- Journal Article
- Title:
- Ischemic burden assessment of myocardial perfusion CT, compared with SPECT using semi-quantitative and quantitative approaches. (1st March 2019)
- Main Title:
- Ischemic burden assessment of myocardial perfusion CT, compared with SPECT using semi-quantitative and quantitative approaches
- Authors:
- Kwon, Osung
Hwang, Hye Jeon
Koo, Hyun Jung
Yang, Dong Hyun
Kang, Hee Jun
Kim, Jeong A.
Moon, Dae Hyuk
Kim, Hyun-Sook
Kang, Joon-Won
Kim, Young-Hak - Abstract:
- Abstract: Background: We aimed to compare the myocardial ischemic burden assessed using semi-quantitative and quantitative analysis of computed tomography-myocardial perfusion imaging (CT-MPI) with that of single-photon emission computed tomography (SPECT). Methods: From 2011 to 2013, 97 patients who underwent CT-MPI and SPECT were evaluated. The extent and severity of perfusion defects were assessed on a 5-point scale using a standard 16-segment model, and were expressed as summed stress score (SSS) and summed difference score (SDS). Receiver operating characteristic (ROC) curves for quantitative parameters were generated for the diagnosis of abnormal perfusion defect (SSS ≥ 4) and presence of ischemia (SDS ≥ 2) on SPECT. Results: On CT-MPI, 298 (19.2%) of the 1552 segments showed perfusion abnormalities during stress, whereas perfusion abnormalities were shown in 179 (11.5%) segments on SPECT-MPI. On a per-person basis, there was good agreement, with intraclass correlation coefficients of 0.78 for SSS and 0.72 for SDS. A significant reduction of attenuation in stress and myocardial perfusion reserve index, along with an increase in % defect volume of CT-MPI, were demonstrated as the degree of perfusion defect or ischemia on SPECT increased. On the ROC curves, % defect volume on CT-MPI demonstrated the highest area under the curve: 0.91 for abnormal perfusion defect and 0.89 (all p < 0.001) for the presence of ischemia on SPECT. Conclusions: Semi-quantitative analysis ofAbstract: Background: We aimed to compare the myocardial ischemic burden assessed using semi-quantitative and quantitative analysis of computed tomography-myocardial perfusion imaging (CT-MPI) with that of single-photon emission computed tomography (SPECT). Methods: From 2011 to 2013, 97 patients who underwent CT-MPI and SPECT were evaluated. The extent and severity of perfusion defects were assessed on a 5-point scale using a standard 16-segment model, and were expressed as summed stress score (SSS) and summed difference score (SDS). Receiver operating characteristic (ROC) curves for quantitative parameters were generated for the diagnosis of abnormal perfusion defect (SSS ≥ 4) and presence of ischemia (SDS ≥ 2) on SPECT. Results: On CT-MPI, 298 (19.2%) of the 1552 segments showed perfusion abnormalities during stress, whereas perfusion abnormalities were shown in 179 (11.5%) segments on SPECT-MPI. On a per-person basis, there was good agreement, with intraclass correlation coefficients of 0.78 for SSS and 0.72 for SDS. A significant reduction of attenuation in stress and myocardial perfusion reserve index, along with an increase in % defect volume of CT-MPI, were demonstrated as the degree of perfusion defect or ischemia on SPECT increased. On the ROC curves, % defect volume on CT-MPI demonstrated the highest area under the curve: 0.91 for abnormal perfusion defect and 0.89 (all p < 0.001) for the presence of ischemia on SPECT. Conclusions: Semi-quantitative analysis of CT-MPI showed good accordance with SPECT. A quantitative approach for CT-MPI, especially % defect volume, may provide additional value in the identification of myocardial perfusion abnormalities. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT01696006 . Highlights: CT-MPI showed good agreement with SPECT by a semi-quantitative approach. The % defect volume demonstrated excellent accuracy in the detection of perfusion abnormality on SPECT. The % defect volume may play an additional role to identify myocardial perfusion defect and ischemia. … (more)
- Is Part Of:
- International journal of cardiology. Volume 278(2019)
- Journal:
- International journal of cardiology
- Issue:
- Volume 278(2019)
- Issue Display:
- Volume 278, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 278
- Issue:
- 2019
- Issue Sort Value:
- 2019-0278-2019-0000
- Page Start:
- 287
- Page End:
- 294
- Publication Date:
- 2019-03-01
- Subjects:
- Coronary artery disease -- Myocardial perfusion imaging -- SPECT -- Computed tomography
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2018.12.046 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9433.xml