141. A preliminary study to evaluate the impact of calculation grid resolution and CT slice thickness on TPS calculated small fields OF. (December 2018)
- Record Type:
- Journal Article
- Title:
- 141. A preliminary study to evaluate the impact of calculation grid resolution and CT slice thickness on TPS calculated small fields OF. (December 2018)
- Main Title:
- 141. A preliminary study to evaluate the impact of calculation grid resolution and CT slice thickness on TPS calculated small fields OF
- Authors:
- Falco, M.D.
Clemente, S.
Fiandra, C.
Agostinelli, S.
Bagalà, P.
Benecchi, G.
Borzì, G.
Bresciani, S.
Broggi, S.
Carbonini, C.
Casale, M.
Casati, M.
Consorti, R.
Corletto, D.
Delana, A.
Esposito, M.
Fusella, M.
Garibaldi, C.
Iervolino, C.
Linsalata, S.
Malatesta, T.
Manco, L.
Marino, C.
Menghi, E.
Moretti, E.
Nardiello, B.
Reggiori, G.
Romagnoli, F.
Soriani, A.
Villaggi, E.
Russo, S.
Mancosu, P.
… (more) - Abstract:
- Abstract: Purpose: Stereotactic Body Radiation Therapy (SBRT) for patients with early stage solid tumor is increasing thanks to modern technologies and integrated image-guided systems. A national study to evaluate the influence of calculation grid resolution and CT slice thickness on small fields calculated in an homogeneous phantom, is in progress. For this purpose, a preliminary investigation that collected different parameters on TPS management at Italian level, was performed. Methods: Twenty-eight centres of the Italian Association of Medical Physics (AIFM) SBRT working group were invited to fill out a questionnaire expressly prepared by expert Medical Physicists using Google Forms. Questions regarded: type of accelerator, MLC characteristics, CT images scan information, Treatment Planning System (TPS) type, strategy used for SBRT plans, small fields OF values, detector/detectors and set-up adopted for measurements. Results: Preliminary results from 28 centers show great heterogeneities. Most centers used LINACs with MLC width ⩽5 mm, 6MV and VMAT technique. 60% of centers used more than one detector to measure OFs and no corrective factor was adopted in small field data. 10 × 10 cm 2 field size was the normalization field. OF data inserted in TPS did not come from a multicenter OF measurements. 1 × 1 cm 2 was the smallest field size measured for 47% of centers. As for TPS, PB, CCC, MC, AAA and deteministic algorithms were used in 3%, 40%, 23%, 27% and 7% of centers,Abstract: Purpose: Stereotactic Body Radiation Therapy (SBRT) for patients with early stage solid tumor is increasing thanks to modern technologies and integrated image-guided systems. A national study to evaluate the influence of calculation grid resolution and CT slice thickness on small fields calculated in an homogeneous phantom, is in progress. For this purpose, a preliminary investigation that collected different parameters on TPS management at Italian level, was performed. Methods: Twenty-eight centres of the Italian Association of Medical Physics (AIFM) SBRT working group were invited to fill out a questionnaire expressly prepared by expert Medical Physicists using Google Forms. Questions regarded: type of accelerator, MLC characteristics, CT images scan information, Treatment Planning System (TPS) type, strategy used for SBRT plans, small fields OF values, detector/detectors and set-up adopted for measurements. Results: Preliminary results from 28 centers show great heterogeneities. Most centers used LINACs with MLC width ⩽5 mm, 6MV and VMAT technique. 60% of centers used more than one detector to measure OFs and no corrective factor was adopted in small field data. 10 × 10 cm 2 field size was the normalization field. OF data inserted in TPS did not come from a multicenter OF measurements. 1 × 1 cm 2 was the smallest field size measured for 47% of centers. As for TPS, PB, CCC, MC, AAA and deteministic algorithms were used in 3%, 40%, 23%, 27% and 7% of centers, respectively. About 29% and 21 % of centers used 3 mm and 2 mm as CT slice thickness, respectively. 50% of centers used 2 mm calculation grid. Conclusions: The influence of the dose calculation resolution and CT slice thickness on small OFs has not been studied yet. This preliminary study, considered as the starting point, highlighted a great spread of answers of the participating center and could be used as a baseline for future investigations. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 151
- Page End:
- 152
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.152 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9409.xml