213. Pre-treatment verification of stereotactic plans using a bi-dimensional diamond detector. (December 2018)
- Record Type:
- Journal Article
- Title:
- 213. Pre-treatment verification of stereotactic plans using a bi-dimensional diamond detector. (December 2018)
- Main Title:
- 213. Pre-treatment verification of stereotactic plans using a bi-dimensional diamond detector
- Authors:
- Talamonti, C.
Bartoli, A.
Scaringella, M.
Baldi, A.
Masi, L.
Pallotta, S.
Bruzzi, M. - Abstract:
- Abstract : Purpose: The aim of this study is to test the performance of a new bi-dimensional diamond dosimeter, manufactured within the DIAPIX and IRTP Italian INFN projects, in pre-treatment verification of high conformal plans. Methods: DIAPIX dosimeter consists of two pCVD diamond matrices (12 × 12 pixels, 2 mm pitch) coupled together covering a total area 2.5 × 4.8 cm 2 with 1 mm dead space between matrices[1] . Dosimetric verifications of lung plans delivered with Cyberknife (CK) and 6 MV photon Elekta Synergy BM (EBM) were compared with the plans calculated with Multiplan Cyberknife and Monaco Elekta TPS. Since some pixels, mainly concentrated in a single matrix, were not fully operational, two measurements in gun-target and three in latero-lateral directions were necessary to cover the full EBM planning area. Bad pixels in both matrices were masked and they were assigned the average value of neighbour pixels and a global 3 × 3 pixel filter was applied. Dose distributions were registered with intensity-based algorithms and γ -index was evaluated with an in-house developed MATLAB routine and focused on the best performing matrix. The passing rate ( γ < 1 ) was evaluated for 3%/3 mm criteria. Results: CK passing rate over the whole dosimeter was 72% and for the EBM was 77%. These values increase to 84% and 85% for CK and EBM respectively just selecting the best performing matrix (Fig. 1). Moreover γ analysis showed that pixels corresponding to the edge of the matrix haveAbstract : Purpose: The aim of this study is to test the performance of a new bi-dimensional diamond dosimeter, manufactured within the DIAPIX and IRTP Italian INFN projects, in pre-treatment verification of high conformal plans. Methods: DIAPIX dosimeter consists of two pCVD diamond matrices (12 × 12 pixels, 2 mm pitch) coupled together covering a total area 2.5 × 4.8 cm 2 with 1 mm dead space between matrices[1] . Dosimetric verifications of lung plans delivered with Cyberknife (CK) and 6 MV photon Elekta Synergy BM (EBM) were compared with the plans calculated with Multiplan Cyberknife and Monaco Elekta TPS. Since some pixels, mainly concentrated in a single matrix, were not fully operational, two measurements in gun-target and three in latero-lateral directions were necessary to cover the full EBM planning area. Bad pixels in both matrices were masked and they were assigned the average value of neighbour pixels and a global 3 × 3 pixel filter was applied. Dose distributions were registered with intensity-based algorithms and γ -index was evaluated with an in-house developed MATLAB routine and focused on the best performing matrix. The passing rate ( γ < 1 ) was evaluated for 3%/3 mm criteria. Results: CK passing rate over the whole dosimeter was 72% and for the EBM was 77%. These values increase to 84% and 85% for CK and EBM respectively just selecting the best performing matrix (Fig. 1). Moreover γ analysis showed that pixels corresponding to the edge of the matrix have a different behaviour and excluding them the passing rate increases to 93% for CK and 95% for EBM. Conclusions: DIAPIX, a bi-dimensional pCVD diamond detector was tested with CK and EBM plans. Its intrinsic characteristics and performance make the DIAPIX pCVD diamond matrix a very innovative and promising technology to be used for pre-treatment verification of stereotactic plans. Future plans are focused on improving pixel contacts to get better device performance and uniformity. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 191
- Page End:
- 192
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.224 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9409.xml