319. Effective Dose Assessment on an Hybrid Equipment: Results and challenges to integrate with MDCT. (December 2018)
- Record Type:
- Journal Article
- Title:
- 319. Effective Dose Assessment on an Hybrid Equipment: Results and challenges to integrate with MDCT. (December 2018)
- Main Title:
- 319. Effective Dose Assessment on an Hybrid Equipment: Results and challenges to integrate with MDCT
- Authors:
- Tosi, G.
Marzo, K.
Chiti, A.
Zanca, F. - Abstract:
- Abstract : Purpose: The aim of this study was to measure, monitor and report effective dose in nuclear medicine and to assess current challenges in integrating these measures with CT. Methods: In 2014 we connected a CT-PET to a dose tracking software and started to collect dose data from CT modality; in late 2015 the software was upgraded to a version which includes a nuclear medicine module for dose tracking. Data from the PET part of the scanner, in terms of administered activity and effective dose, were also collected. Results: Data from 12000 CT doses and 3700 PET doses were collected, mostly from: Whole Body (WB) 18 F-FDG (63.2%), WB 11 C-Choline (12.8%), WB 68 Ga-DOTATOC (5.5%), Head 11 C-Methionine for a total of 18.4% of the whole activity of the scanner. CT mean DLP (mGy∗cm) data values were (range between brackets): WB 18 F-FDG 1486.3 (76.1-7700.9), WB 11 C-Choline 2451.9 (290.9-5023.1), WB 68 Ga-DOTATOC 1183.8 (41.0-3728.4) and Head 11 C-Methionine 766.7 (52.3-2326.9). Mean effective doses (mSv) were: WB 18 F-FDG 15.3 ± 4.7, WB 11 C-Choline 26.5 ± 5.6, WB 68 Ga 13.4 ± 3.7 and Head 11 C-Methionine 1.2 ± 0.7. Mean administered activities (MBq) and effective doses (mSv) for radiopharmaceuticals used in PET were: WB 18 F-FDG 335.9-6.4, Head 11 C-Methionine 294.6-2.5, WB 68 Ga-DOTATOC 168.3-3.5 and WB 11 C-Choline 322.2–1.5. The mean total effective doses (mSv) due to both modality were: WB 18 F-FDG 21.7 ± 4.9, Head 11 C-Methionine 3.7 ± 0.8, WB 11 C-Choline 27.9 ± 5.6Abstract : Purpose: The aim of this study was to measure, monitor and report effective dose in nuclear medicine and to assess current challenges in integrating these measures with CT. Methods: In 2014 we connected a CT-PET to a dose tracking software and started to collect dose data from CT modality; in late 2015 the software was upgraded to a version which includes a nuclear medicine module for dose tracking. Data from the PET part of the scanner, in terms of administered activity and effective dose, were also collected. Results: Data from 12000 CT doses and 3700 PET doses were collected, mostly from: Whole Body (WB) 18 F-FDG (63.2%), WB 11 C-Choline (12.8%), WB 68 Ga-DOTATOC (5.5%), Head 11 C-Methionine for a total of 18.4% of the whole activity of the scanner. CT mean DLP (mGy∗cm) data values were (range between brackets): WB 18 F-FDG 1486.3 (76.1-7700.9), WB 11 C-Choline 2451.9 (290.9-5023.1), WB 68 Ga-DOTATOC 1183.8 (41.0-3728.4) and Head 11 C-Methionine 766.7 (52.3-2326.9). Mean effective doses (mSv) were: WB 18 F-FDG 15.3 ± 4.7, WB 11 C-Choline 26.5 ± 5.6, WB 68 Ga 13.4 ± 3.7 and Head 11 C-Methionine 1.2 ± 0.7. Mean administered activities (MBq) and effective doses (mSv) for radiopharmaceuticals used in PET were: WB 18 F-FDG 335.9-6.4, Head 11 C-Methionine 294.6-2.5, WB 68 Ga-DOTATOC 168.3-3.5 and WB 11 C-Choline 322.2–1.5. The mean total effective doses (mSv) due to both modality were: WB 18 F-FDG 21.7 ± 4.9, Head 11 C-Methionine 3.7 ± 0.8, WB 11 C-Choline 27.9 ± 5.6 and WB 68 Ga-DOTATOC 16.9 ± 2.8. Conclusions: The implementation of a dose tracking system to nuclear medicine is of great value for accurate and regular recording, reporting and analysis of patient's effective doses. It can help to improve the evaluation of radiation exposures in the clinical practice. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 257
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.328 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9408.xml