236. Temporal stability of MRI: A simple QA for advanced techniques. (December 2018)
- Record Type:
- Journal Article
- Title:
- 236. Temporal stability of MRI: A simple QA for advanced techniques. (December 2018)
- Main Title:
- 236. Temporal stability of MRI: A simple QA for advanced techniques
- Authors:
- Piffer, S.
Fedeli, L.
Busoni, S.
Gori, C.
Belli, G. - Abstract:
- Abstract : Purpose: MRI scanner performance temporal stability is fundamental aspect in several multi-parametric exams (like diffusion, functional and spectroscopy) effect of order of few percent may be clinically relevant. Revised version of Friedman protocol (JMRI, 23 -2006) was adopted to check stability of scanners over time on weekly basis. Linewidth of water peak in MR spectroscopy after optimization is considered as well. Results over a long period survey of several clinical scanners are reported. Methods: The purpose of the procedure is to measure time stability of the scanners in conditions that are as similar as possible to the clinical settings. The head coil and scanning sequence used clinically were tested. A time series of 200 images of QA vendor phantom is collected. The automated analysis provides information about signal intensity, uniformity, magnitude spectrum, radius of decorrelation (RdC), short term reproducibility, SNR and signal fluctuation to noise ratio. RdC represents the size of ROI for which the main source of signal noise is systematic and not statistic. With same setup, linewidth after B0 homogeneity optimisation is measured. Data were acquired on four 1.5 T MRI clinical scanners, on a 4 years time interval. Results: Data fluctuations of considered parameters are of order of few percent (varying between 1% and 9%), significant variations have been observer after component change and software upgrade. Fourier analysis of short term signalAbstract : Purpose: MRI scanner performance temporal stability is fundamental aspect in several multi-parametric exams (like diffusion, functional and spectroscopy) effect of order of few percent may be clinically relevant. Revised version of Friedman protocol (JMRI, 23 -2006) was adopted to check stability of scanners over time on weekly basis. Linewidth of water peak in MR spectroscopy after optimization is considered as well. Results over a long period survey of several clinical scanners are reported. Methods: The purpose of the procedure is to measure time stability of the scanners in conditions that are as similar as possible to the clinical settings. The head coil and scanning sequence used clinically were tested. A time series of 200 images of QA vendor phantom is collected. The automated analysis provides information about signal intensity, uniformity, magnitude spectrum, radius of decorrelation (RdC), short term reproducibility, SNR and signal fluctuation to noise ratio. RdC represents the size of ROI for which the main source of signal noise is systematic and not statistic. With same setup, linewidth after B0 homogeneity optimisation is measured. Data were acquired on four 1.5 T MRI clinical scanners, on a 4 years time interval. Results: Data fluctuations of considered parameters are of order of few percent (varying between 1% and 9%), significant variations have been observer after component change and software upgrade. Fourier analysis of short term signal doesn't show periodic noise. Short term reproducibility is below 1% for all considered scanners. RdC is 18 pixels for two scanners and 6 pixels for other. No significant variation have been observed during temporal series. Linewidth is stable within 6%. Conclusions: Regular check of parameter stability provides strong feedback regarding scanner performances, and may allow to predict possible malfunctioning. Proposed protocol may be used as basic QA in advanced MRI technique. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 207
- Page End:
- 208
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.247 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9408.xml