36. Optimization of the acquisition threshold of Photon Counting Detectors (PCDs) used in X-ray medical imaging. (December 2018)
- Record Type:
- Journal Article
- Title:
- 36. Optimization of the acquisition threshold of Photon Counting Detectors (PCDs) used in X-ray medical imaging. (December 2018)
- Main Title:
- 36. Optimization of the acquisition threshold of Photon Counting Detectors (PCDs) used in X-ray medical imaging
- Authors:
- Di Trapani, V.
Brombal, L.
Donato, S.
Golosio, B.
Longo, R.
Oliva, P.
Rigon, L.
Delogu, P. - Abstract:
- Abstract : Purpose: PCDs with energy discrimination led to new possibilities of improving the quality of X-ray medical images. PCDs are direct detection devices in which the charge delivered by a single interacting photon is directly collected and discriminated at single pixels level. The limit of high densely pixelated PCDs is the charge sharing which can lead to multiple counts from a single interaction degrading the spatial resolution of the system. Increasing the discrimination threshold, multiple counts can be partially or totally removed from images improving the spatial resolution at the cost of a reduction of the detection area of single pixels with a consequent loss of statistics. This work aims to show a simple method to find the optimal threshold which gives the best trade-off between spatial resolution and statistics. Methods: The acquisitions have been performed at the SYRMEP beamline (Elettra Trieste) using the tomographic experimental set-up of INFN project SYnchrotron Radiation MAmmography (SYRMA-3D). SYRMA-3D uses 'Pixirad-8', a PCD with CdTe sensor and a pixel size of 60 μm. For this study, we used a monochromatic beam of 38 keV acquiring a set of images of an edge and a set of images of the beam with different detection thresholds. The two sets of images have been used respectively for the measurement of the Modulation transfer function (MTF) and the noise power spectrum (NPS). Combining both NPS and MTF the Number of Equivalent Quanta (NEQ) can beAbstract : Purpose: PCDs with energy discrimination led to new possibilities of improving the quality of X-ray medical images. PCDs are direct detection devices in which the charge delivered by a single interacting photon is directly collected and discriminated at single pixels level. The limit of high densely pixelated PCDs is the charge sharing which can lead to multiple counts from a single interaction degrading the spatial resolution of the system. Increasing the discrimination threshold, multiple counts can be partially or totally removed from images improving the spatial resolution at the cost of a reduction of the detection area of single pixels with a consequent loss of statistics. This work aims to show a simple method to find the optimal threshold which gives the best trade-off between spatial resolution and statistics. Methods: The acquisitions have been performed at the SYRMEP beamline (Elettra Trieste) using the tomographic experimental set-up of INFN project SYnchrotron Radiation MAmmography (SYRMA-3D). SYRMA-3D uses 'Pixirad-8', a PCD with CdTe sensor and a pixel size of 60 μm. For this study, we used a monochromatic beam of 38 keV acquiring a set of images of an edge and a set of images of the beam with different detection thresholds. The two sets of images have been used respectively for the measurement of the Modulation transfer function (MTF) and the noise power spectrum (NPS). Combining both NPS and MTF the Number of Equivalent Quanta (NEQ) can be determined. The NEQ summarizes both informations about spatial resolution and noise and is an useful metrics for the global image quality assessment. Results: The comparison between NEQ curves shows that lower thresholds give better NEQ response. Conclusions: The increase of the discrimination threshold improves the spatial resolution but worsens the noise. The global image quality, measured using NEQ, is higher for lower thresholds. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 84
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.046 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9408.xml