Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable. (23rd January 2019)
- Record Type:
- Journal Article
- Title:
- Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable. (23rd January 2019)
- Main Title:
- Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable
- Authors:
- Wiens, Casey
Denton, William
Schieber, Molly N.
Hartley, Ryan
Marmelat, Vivien
Myers, Sara A.
Yentes, Jennifer M. - Abstract:
- Abstract: The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the FeedbackTM for a 5-minute familiarization followed by a 16-minute experimental trial. They returned within one week and completed a 5-minute familiarization followed by a 16-minute experimental trial each for FeedbackTM and FixedTM conditions. Mean walking speed and step time, length, width, and speed means and coefficient of variation were calculated from all experimental conditions. Step time, length, width, and speed gait dynamics were analyzed using detrended fluctuation analysis. Mean differences between experimental trials were determined using ANOVAs and reliability between FeedbackTM sessions was determined by intraclass correlation coefficient. No difference was found in mean walking speed nor spatiotemporal variables, with the exception of step width, between the experimental trials. All mean spatiotemporal variables demonstrated good to excellent reliability between sessions, while coefficient of variation was not reliable. Gait dynamics of step time, length, width, and speed were significantly more persistent during the FeedbackTM condition compared to FixedTM, especially step speed. However, gait dynamics demonstrated fair to poor reliabilityAbstract: The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the FeedbackTM for a 5-minute familiarization followed by a 16-minute experimental trial. They returned within one week and completed a 5-minute familiarization followed by a 16-minute experimental trial each for FeedbackTM and FixedTM conditions. Mean walking speed and step time, length, width, and speed means and coefficient of variation were calculated from all experimental conditions. Step time, length, width, and speed gait dynamics were analyzed using detrended fluctuation analysis. Mean differences between experimental trials were determined using ANOVAs and reliability between FeedbackTM sessions was determined by intraclass correlation coefficient. No difference was found in mean walking speed nor spatiotemporal variables, with the exception of step width, between the experimental trials. All mean spatiotemporal variables demonstrated good to excellent reliability between sessions, while coefficient of variation was not reliable. Gait dynamics of step time, length, width, and speed were significantly more persistent during the FeedbackTM condition compared to FixedTM, especially step speed. However, gait dynamics demonstrated fair to poor reliability between FeedbackTM sessions. When walking on the FeedbackTM, users maintain a consistent set point, yet the gait dynamics around the mean are different when compared to walking on a FixedTM. In addition, spatiotemporal gait dynamics and variability may not be consistent across separate days when using the FeedbackTM. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 83(2019)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 83(2019)
- Issue Display:
- Volume 83, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 83
- Issue:
- 2019
- Issue Sort Value:
- 2019-0083-2019-0000
- Page Start:
- 221
- Page End:
- 226
- Publication Date:
- 2019-01-23
- Subjects:
- Feedback-controlled treadmill -- Self-paced treadmill -- Detrended fluctuation analysis -- Gait dynamics -- Reliability
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2018.11.051 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9413.xml