56. Low-dose protocol for computed tomography angiography of thoracic aorta with ASiR-V iterative reconstruction. (December 2018)
- Record Type:
- Journal Article
- Title:
- 56. Low-dose protocol for computed tomography angiography of thoracic aorta with ASiR-V iterative reconstruction. (December 2018)
- Main Title:
- 56. Low-dose protocol for computed tomography angiography of thoracic aorta with ASiR-V iterative reconstruction
- Authors:
- Origgi, D.
Budascu, D.
Consiglio, E.
Marco, P. De
Emiro, F.
Annoni, A. - Abstract:
- Abstract : Purpose: To assess the feasibility of a Computed Tomography Angiography (CTA) protocol with low kVp and the new iterative reconstruction (IR) algorithm ASiR-V. Methods: 63 patients (43 men and 20 women) were scanned on a 256 slices CT Revolution in prospective axial mode, with 80 kVp and mA ranging from 350 to 600 depending on patient BMI. Images were reconstructed with Filtered Back-projection (FBP) and with ASiR-V ranging from 20% to 100%. Images were analyzed quantitatively, placing ROIs in the ascending aorta, aortic arch and descending aorta to evaluate noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratio for all patients and for all levels of ASiR-V. Qualitative image evaluation was performed by two radiologist (both >10 years of experience) using the LIKERT scale. For all patients effective dose (E) is calculated from DLP. In addition, a comparison with the former clinical protocol on a CT Discovery with ASiR instead of ASiR-V was performed. Results: Passing from FBP to ASiR-V 100%, noise is reduced on average up to 31%, while SNR and CNR are improved on average up to 46%. Subjective analysis gives the highest LIKERT score to the images reconstructed with ASiR-V 60% (3.8 ± 0.3 for reader 1, 3.8 ± 0.6 for reader 2–k = 0.87). With this IR level, noise is reduced by 20%, while SNR and CNR are improved by 25%. In a subpopulation with BMI >30, ASiR-V 80% resulted in the best compromise between dose reduction and image quality. Considering the same 50%Abstract : Purpose: To assess the feasibility of a Computed Tomography Angiography (CTA) protocol with low kVp and the new iterative reconstruction (IR) algorithm ASiR-V. Methods: 63 patients (43 men and 20 women) were scanned on a 256 slices CT Revolution in prospective axial mode, with 80 kVp and mA ranging from 350 to 600 depending on patient BMI. Images were reconstructed with Filtered Back-projection (FBP) and with ASiR-V ranging from 20% to 100%. Images were analyzed quantitatively, placing ROIs in the ascending aorta, aortic arch and descending aorta to evaluate noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratio for all patients and for all levels of ASiR-V. Qualitative image evaluation was performed by two radiologist (both >10 years of experience) using the LIKERT scale. For all patients effective dose (E) is calculated from DLP. In addition, a comparison with the former clinical protocol on a CT Discovery with ASiR instead of ASiR-V was performed. Results: Passing from FBP to ASiR-V 100%, noise is reduced on average up to 31%, while SNR and CNR are improved on average up to 46%. Subjective analysis gives the highest LIKERT score to the images reconstructed with ASiR-V 60% (3.8 ± 0.3 for reader 1, 3.8 ± 0.6 for reader 2–k = 0.87). With this IR level, noise is reduced by 20%, while SNR and CNR are improved by 25%. In a subpopulation with BMI >30, ASiR-V 80% resulted in the best compromise between dose reduction and image quality. Considering the same 50% IR level for ASiR and ASiR-V, with ASiR-V we observe noise reduction (10–27%), CNR (12–40%) and SNR(6–32%) improvement, while dose decreases form 1.5 to 1 mSv. Conclusions: The new proposed protocol at 80 kVp tube voltage and 60% ASiR-V allows high image quality and mean doses of only 1 mSv. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 98
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.066 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9408.xml