177. Feasibility of SBRT-VMAT as an alternative to HDR brachytherapy for vaginal cuff. A dosimetric study. (December 2018)
- Record Type:
- Journal Article
- Title:
- 177. Feasibility of SBRT-VMAT as an alternative to HDR brachytherapy for vaginal cuff. A dosimetric study. (December 2018)
- Main Title:
- 177. Feasibility of SBRT-VMAT as an alternative to HDR brachytherapy for vaginal cuff. A dosimetric study
- Authors:
- Cilla, S.
Mattiucci, G.C.
Macchia, G.
Deodato, F.
Ianiro, A.
Azario, L.
Morganti, A.G.
Valentini, V. - Abstract:
- Abstract: Purpose: We evaluate the role of stereotactic body radiotherapy (SBRT) using VMAT technique as an alternative to high-dose rate brachytherapy (HDR-BRT) in the treatment of vaginal cuff in postoperative endometrial cancer. Methods: CT scans of 5 patients were used in this study. The CTV was defined as the 0.5 cm tissue around the applicator (then subtracting the applicator). Total dose was 30 Gy delivered in 5 fractions. In HDR-BRT, dose was prescribed at a distance of 0.5 cm from the surface applicator. For VMAT diation, a PTV was obtained from CTV by an expansion of 3 mm. Two VMAT plans were generated using a full arc rotation. The first plan was optimized with an anatomy-based optimization module (AB_VMAT) using a 1 mm MLC beam margin to enhance dose fallout. The second plan was generated with a full-inverse planning module (FI_VMAT). Conformity (CI100, CI50), gradient (GI), homogeneity (HI) indexes and equivalent uniform dose (EUD) were calculated. A Kruskal-Wallis ANOVA was performed. Results: VMAT plans provided targets coverage comparable with HDR (p < 0.05). Dose distributions were more heterogeneous with HDR: Dmean were 144.2% for CTV in HDR and 118.0 and 109.1% for PTV in AB_VMAT and FI_VMAT, respectively. The mean values of EUD for CTV were: HDR 40.9 Gy; AB_VMAT 39.0 Gy; FI_VMAT 33.3 Gy. GI indexes were 2.81, 3.37 and 4.15 for HDR, AB_VMAT and FI_VMAT, respectively. Dmean and maximal doses to 2 cc for rectum and bladder were lower in HDR-BRT plansAbstract: Purpose: We evaluate the role of stereotactic body radiotherapy (SBRT) using VMAT technique as an alternative to high-dose rate brachytherapy (HDR-BRT) in the treatment of vaginal cuff in postoperative endometrial cancer. Methods: CT scans of 5 patients were used in this study. The CTV was defined as the 0.5 cm tissue around the applicator (then subtracting the applicator). Total dose was 30 Gy delivered in 5 fractions. In HDR-BRT, dose was prescribed at a distance of 0.5 cm from the surface applicator. For VMAT diation, a PTV was obtained from CTV by an expansion of 3 mm. Two VMAT plans were generated using a full arc rotation. The first plan was optimized with an anatomy-based optimization module (AB_VMAT) using a 1 mm MLC beam margin to enhance dose fallout. The second plan was generated with a full-inverse planning module (FI_VMAT). Conformity (CI100, CI50), gradient (GI), homogeneity (HI) indexes and equivalent uniform dose (EUD) were calculated. A Kruskal-Wallis ANOVA was performed. Results: VMAT plans provided targets coverage comparable with HDR (p < 0.05). Dose distributions were more heterogeneous with HDR: Dmean were 144.2% for CTV in HDR and 118.0 and 109.1% for PTV in AB_VMAT and FI_VMAT, respectively. The mean values of EUD for CTV were: HDR 40.9 Gy; AB_VMAT 39.0 Gy; FI_VMAT 33.3 Gy. GI indexes were 2.81, 3.37 and 4.15 for HDR, AB_VMAT and FI_VMAT, respectively. Dmean and maximal doses to 2 cc for rectum and bladder were lower in HDR-BRT plans compared to AB_VMAT and FI:VMAT (rectum Dmean: 39.8% vs 47.4% and 53.0%; bladder Dmean: 35.4% vs 40.4% and 46.1%; rectum D2cc: 104.8% vs 108.0% and 116.2%; bladder D2cc: 86.64% vs 94.0% and 100.0%). Conclusions: HDR-BRT provided superior dose distribution with respect to VMAT. AB_VMAT plans tend to better mimic the HDR dose distribution, providing a fast, safe and reasonable alternative. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 172
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.188 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9408.xml