168. Evaluation of a machine QA software tool for MLC performance checks. (December 2018)
- Record Type:
- Journal Article
- Title:
- 168. Evaluation of a machine QA software tool for MLC performance checks. (December 2018)
- Main Title:
- 168. Evaluation of a machine QA software tool for MLC performance checks
- Authors:
- Strolin, S.
Grimaldi, P.
Nigro, R.
Riccardi, S.
Franza, N. - Abstract:
- Abstract: Purpose: One of the main requirement for a correct intensity modulated treatment (IMRT) delivery, is a periodic check of Multileaf Collimator (MLC) parameters. In some Treatment Planning System (TPS), the Dosimetric Leaf Gap (DLG) is one of the most important parameter for the correct calculation of dose distribution when using dynamic MLC. The purpose of this work is to evaluate the feasibility and time saving in using a dedicated machine quality assurance (QA) software tool to monitor over time the DLG parameter and leaves positions. Methods: Two 6 MV Linac equipped with a 120 leaf MLC were compared to check the measured constancy of the DLG and leaves positions through use of a 3D diode array equipped with a dedicated machine QA software tool. The MLC checks were performed at 50° and 320° gantry angles due to phantom's plate geometry. In this way it was possible also to verify gravity effects on leaves banks. The analysis was carried out with a version of picket fence test implemented in the software. Results: The Veroli mean DLG values was 2, 0 ± 0.4 mm for 50° gantry angle and 2.1 ± 0.5 mm for 320° gantry angle. The Rieti mean DLG values was 1.9 ± 0.1 for 50° gantry angle and 2.0 ± 0.1 mm for 320° gantry angle. The check on the leaves movement has shown gravity effect on two different angles. In particular the Rieti DLG value carried out at gantry 50° was 1.6 ± 0.1 mm when there was a problem to leaf motor. Conclusion: The picket fence test, originally usedAbstract: Purpose: One of the main requirement for a correct intensity modulated treatment (IMRT) delivery, is a periodic check of Multileaf Collimator (MLC) parameters. In some Treatment Planning System (TPS), the Dosimetric Leaf Gap (DLG) is one of the most important parameter for the correct calculation of dose distribution when using dynamic MLC. The purpose of this work is to evaluate the feasibility and time saving in using a dedicated machine quality assurance (QA) software tool to monitor over time the DLG parameter and leaves positions. Methods: Two 6 MV Linac equipped with a 120 leaf MLC were compared to check the measured constancy of the DLG and leaves positions through use of a 3D diode array equipped with a dedicated machine QA software tool. The MLC checks were performed at 50° and 320° gantry angles due to phantom's plate geometry. In this way it was possible also to verify gravity effects on leaves banks. The analysis was carried out with a version of picket fence test implemented in the software. Results: The Veroli mean DLG values was 2, 0 ± 0.4 mm for 50° gantry angle and 2.1 ± 0.5 mm for 320° gantry angle. The Rieti mean DLG values was 1.9 ± 0.1 for 50° gantry angle and 2.0 ± 0.1 mm for 320° gantry angle. The check on the leaves movement has shown gravity effect on two different angles. In particular the Rieti DLG value carried out at gantry 50° was 1.6 ± 0.1 mm when there was a problem to leaf motor. Conclusion: The picket fence test, originally used with radiographic film to check the reproducibility of leaf gap, is extended in this machine QA software tool, including checks for gap width and leaf positions. This tool can be used as a routine MLC QA check for mean leaf deviation, DLG, and absolute positions of the leaves. … (more)
- Is Part Of:
- Physica medica. Volume 56(2018)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 56(2018)Supplement 2
- Issue Display:
- Volume 56, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2018-0056-0002-0000
- Page Start:
- 168
- Page End:
- Publication Date:
- 2018-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.04.179 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9408.xml