Quality assurance of Cyberknife robotic stereotactic radiosurgery using an angularly independent silicon detector. Issue 1 (22nd November 2018)
- Record Type:
- Journal Article
- Title:
- Quality assurance of Cyberknife robotic stereotactic radiosurgery using an angularly independent silicon detector. Issue 1 (22nd November 2018)
- Main Title:
- Quality assurance of Cyberknife robotic stereotactic radiosurgery using an angularly independent silicon detector
- Authors:
- Alhujaili, Sultan Fahad
Biasi, Giordano
Alzorkany, Faisal
Grogan, Garry
Al Kafi, Muhammed A.
Lane, Jonathan
Hug, Benjamin
Aldosari, Abdullah H.
Alshaikh, Sami
Farzad, Pejman Rowshan
Ebert, Martin A.
Moftah, Belal
Rosenfeld, Anatoly B.
Petasecca, Marco - Abstract:
- Abstract: Purpose: The aim of this work was to evaluate the use of an angularly independent silicon detector (edgeless diodes) developed for dosimetry in megavoltage radiotherapy for Cyberknife in a phantom and for patient quality assurance (QA). Method: The characterization of the edgeless diodes has been performed on Cyberknife with fixed and IRIS collimators. The edgeless diode probes were tested in terms of basic QA parameters such as measurements of tissue‐phantom ratio (TPR), output factor and off‐axis ratio. The measurements were performed in both water and water‐equivalent phantoms. In addition, three patient‐specific plans have been delivered to a lung phantom with and without motion and dose measurements have been performed to verify the ability of the diodes to work as patient‐specific QA devices. The data obtained by the edgeless diodes have been compared to PTW 60016, SN edge, PinPoint ionization chamber, Gafchromic EBT3 film, and treatment planning system (TPS). Results: The TPR measurement performed by the edgeless diodes show agreement within 2.2% with data obtained with PTW 60016 diode for all the field sizes. Output factor agrees within 2.6% with that measured by SN EDGE diodes corrected for their field size dependence. The beam profiles' measurements of edgeless diodes match SN EDGE diodes with a measured full width half maximum (FWHM) within 2.3% and penumbra widths within 0.148 mm. Patient‐specific QA measurements demonstrate an agreement within 4.72% inAbstract: Purpose: The aim of this work was to evaluate the use of an angularly independent silicon detector (edgeless diodes) developed for dosimetry in megavoltage radiotherapy for Cyberknife in a phantom and for patient quality assurance (QA). Method: The characterization of the edgeless diodes has been performed on Cyberknife with fixed and IRIS collimators. The edgeless diode probes were tested in terms of basic QA parameters such as measurements of tissue‐phantom ratio (TPR), output factor and off‐axis ratio. The measurements were performed in both water and water‐equivalent phantoms. In addition, three patient‐specific plans have been delivered to a lung phantom with and without motion and dose measurements have been performed to verify the ability of the diodes to work as patient‐specific QA devices. The data obtained by the edgeless diodes have been compared to PTW 60016, SN edge, PinPoint ionization chamber, Gafchromic EBT3 film, and treatment planning system (TPS). Results: The TPR measurement performed by the edgeless diodes show agreement within 2.2% with data obtained with PTW 60016 diode for all the field sizes. Output factor agrees within 2.6% with that measured by SN EDGE diodes corrected for their field size dependence. The beam profiles' measurements of edgeless diodes match SN EDGE diodes with a measured full width half maximum (FWHM) within 2.3% and penumbra widths within 0.148 mm. Patient‐specific QA measurements demonstrate an agreement within 4.72% in comparison with TPS. Conclusion: The edgeless diodes have been proved to be an excellent candidate for machine and patient QA for Cyberknife reproducing commercial dosimetry device measurements without need of angular dependence corrections. However, further investigation is required to evaluate the effect of their dose rate dependence on complex brain cancer dose verification. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 1(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 1(2019)
- Issue Display:
- Volume 20, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2019-0020-0001-0000
- Page Start:
- 76
- Page End:
- 88
- Publication Date:
- 2018-11-22
- Subjects:
- angular dependence -- cyberknife -- silicon detector -- small field dosimetry -- stereotactic radiosurgery
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12496 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9411.xml