Dose prescription with spatial uncertainty for peripheral lung SBRT. Issue 1 (14th December 2018)
- Record Type:
- Journal Article
- Title:
- Dose prescription with spatial uncertainty for peripheral lung SBRT. Issue 1 (14th December 2018)
- Main Title:
- Dose prescription with spatial uncertainty for peripheral lung SBRT
- Authors:
- Bedford, James L.
Blasiak‐Wal, Irena
Hansen, Vibeke N. - Abstract:
- Abstract: Current clinical practice is to prescribe to 95% of the planning target volume (PTV) in 4D stereotactic body radiotherapy (SBRT) for lung. Frequently the PTV margin has a very low physical density so that the internal target volume (ITV) receives an unnecessarily high dose. This study investigates the alternative of prescribing to the ITV while including the effects of positional uncertainties. Five patients were retrospectively studied with volumetric modulated arc therapy treatment plans. Five plans were produced for each patient: a static plan prescribed to PTV D 95%, three probabilistic plans prescribed to ITV D 95% and a static plan re‐prescribed to ITV D 95% after inverse planning. For the three probabilistic plans, the scatter kernel in the dose calculation was convolved with a spatial uncertainty distribution consisting of either a uniform distribution extending ±5 mm in the three orthogonal directions, a distribution consisting of delta functions at ±5 mm, or a Gaussian distribution with standard deviation 5 mm. Median ITV D 50% is 23% higher than the prescribed dose for static planning and only 10% higher than the prescribed dose for prescription to the ITV. The choice of uncertainty distribution has less than 2% effect on the median ITV dose. Re‐prescribing a static plan and evaluating with a probabilistic dose calculation results in a median ITV D 95% which is 1.5% higher than when planning probabilistically. This study shows that a robust probabilisticAbstract: Current clinical practice is to prescribe to 95% of the planning target volume (PTV) in 4D stereotactic body radiotherapy (SBRT) for lung. Frequently the PTV margin has a very low physical density so that the internal target volume (ITV) receives an unnecessarily high dose. This study investigates the alternative of prescribing to the ITV while including the effects of positional uncertainties. Five patients were retrospectively studied with volumetric modulated arc therapy treatment plans. Five plans were produced for each patient: a static plan prescribed to PTV D 95%, three probabilistic plans prescribed to ITV D 95% and a static plan re‐prescribed to ITV D 95% after inverse planning. For the three probabilistic plans, the scatter kernel in the dose calculation was convolved with a spatial uncertainty distribution consisting of either a uniform distribution extending ±5 mm in the three orthogonal directions, a distribution consisting of delta functions at ±5 mm, or a Gaussian distribution with standard deviation 5 mm. Median ITV D 50% is 23% higher than the prescribed dose for static planning and only 10% higher than the prescribed dose for prescription to the ITV. The choice of uncertainty distribution has less than 2% effect on the median ITV dose. Re‐prescribing a static plan and evaluating with a probabilistic dose calculation results in a median ITV D 95% which is 1.5% higher than when planning probabilistically. This study shows that a robust probabilistic approach to planning SBRT lung treatments results in the ITV receiving a dose closer to the intended prescription. The exact form of the uncertainty distribution is not found to be critical. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 1(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 1(2019)
- Issue Display:
- Volume 20, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2019-0020-0001-0000
- Page Start:
- 160
- Page End:
- 167
- Publication Date:
- 2018-12-14
- Subjects:
- dose prescription -- probabilistic treatment planning -- SBRT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12504 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9411.xml