Using CFD simulations to develop an upward airflow displacement ventilation system for manure-belt layer houses to improve the indoor environment. (February 2019)
- Record Type:
- Journal Article
- Title:
- Using CFD simulations to develop an upward airflow displacement ventilation system for manure-belt layer houses to improve the indoor environment. (February 2019)
- Main Title:
- Using CFD simulations to develop an upward airflow displacement ventilation system for manure-belt layer houses to improve the indoor environment
- Authors:
- Tong, Xinjie
Hong, Se-Woon
Zhao, Lingying - Abstract:
- Abstract : Heat stress and disease outbreak result in significant losses in large-scale egg productions. New ventilation systems are needed for large-scale layer production facilities to provide safe and uniform indoor environment, especially in the changing climate of global warming. This study developed a new ventilation system, upward airflow displacement ventilation (UADV) system, which allows fresh air to enter a layer house through air ducts located at the bottom of the cages, move upward by thermal buoyancy caused by hens and static pressure differences caused by exhaust fans, and ultimately exit the house through the fans installed on the roof. The performance of the UADV system was evaluated in comparison with a typical tunnel ventilation (TV) system in terms of air-exchange effectiveness, thermal environment, and airborne pathogen dispersal in both summer and winter using a validated Computational Fluid Dynamics (CFD) model. The results showed that the UADV system resulted in 46%–129% greater air-exchange effectiveness within the cages and provided a more homogeneous thermal environment with 9.4% less heat stress in summer and 68% less cold stress in winter compared with the TV system. In addition, transport of pathogens was largely inhibited in the UADV system compared with the TV system due to upward airflow and minimum air mixing across the cages. When coupled with sensible cooling of supply air, UADV system can further improve the thermal environment with aAbstract : Heat stress and disease outbreak result in significant losses in large-scale egg productions. New ventilation systems are needed for large-scale layer production facilities to provide safe and uniform indoor environment, especially in the changing climate of global warming. This study developed a new ventilation system, upward airflow displacement ventilation (UADV) system, which allows fresh air to enter a layer house through air ducts located at the bottom of the cages, move upward by thermal buoyancy caused by hens and static pressure differences caused by exhaust fans, and ultimately exit the house through the fans installed on the roof. The performance of the UADV system was evaluated in comparison with a typical tunnel ventilation (TV) system in terms of air-exchange effectiveness, thermal environment, and airborne pathogen dispersal in both summer and winter using a validated Computational Fluid Dynamics (CFD) model. The results showed that the UADV system resulted in 46%–129% greater air-exchange effectiveness within the cages and provided a more homogeneous thermal environment with 9.4% less heat stress in summer and 68% less cold stress in winter compared with the TV system. In addition, transport of pathogens was largely inhibited in the UADV system compared with the TV system due to upward airflow and minimum air mixing across the cages. When coupled with sensible cooling of supply air, UADV system can further improve the thermal environment with a much lower ventilation rate under extremely hot and humid weather conditions. However, higher ventilation rates were more effective for reducing potential pathogen dispersal. Highlights: A new ventilation system (UADV) was developed for manure-belt layer house. UADV system improves ventilation effectiveness within the cages by 46%–129%. UADV system improves indoor thermal environment with higher homogeneity. UADV system reduces heat stress by 9.4% in summer and cold stress by 68% in winter. UADV system allowed for better disease control due to upward airflow pattern. … (more)
- Is Part Of:
- Biosystems engineering. Volume 178(2019)
- Journal:
- Biosystems engineering
- Issue:
- Volume 178(2019)
- Issue Display:
- Volume 178, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 178
- Issue:
- 2019
- Issue Sort Value:
- 2019-0178-2019-0000
- Page Start:
- 294
- Page End:
- 308
- Publication Date:
- 2019-02
- Subjects:
- Disease outbreak -- Displacement ventilation -- Heat stress -- Air velocity effect -- Ventilation effectiveness -- Thermal uniformity
Bioengineering -- Periodicals
Agricultural engineering -- Periodicals
Biological systems -- Periodicals
Génie rural -- Périodiques
Systèmes biologiques -- Périodiques
631 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15375110 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biosystemseng.2018.08.006 ↗
- Languages:
- English
- ISSNs:
- 1537-5110
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2089.670500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9388.xml