Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey. (February 2019)
- Record Type:
- Journal Article
- Title:
- Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey. (February 2019)
- Main Title:
- Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey
- Authors:
- Schmitz, Marweh
Schubert, Dirk W.
Kaschta, Joachim
Daenicke, Jonas
Walter, Bastian L.
Horch, Raymund E. - Abstract:
- Abstract: Objectives: Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing awareness of concerns about product liability the question of whether short-time irrigation of implants with antimicrobial substances during the operative procedure would potentially alter the integrity of the implant shell has attracted legal and medical interest. In this study we therefore investigated whether irrigating breast implants with antimicrobials commonly used in clinical practice with a clinically relevant application time would affect the physical integrity of the implant shell. Materials and methods: Samples, which were previously punched from the shell of explanted standard silicone gel filled breast implants in a defined way, were exposed to different disinfectant solutions for two minutes. Multiple defined specimens from 5 different explants from 4 different producers (including PIP) were tested. The testing included tensile strength and disruption tests. Results: In our prospective test series we could not find a significant influence of a single distinct disinfectant on silicone shell implant surfaces. Conclusion: Despite the potential legal implications that might be considered when a surgeon manipulates an implant with disinfectantsAbstract: Objectives: Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing awareness of concerns about product liability the question of whether short-time irrigation of implants with antimicrobial substances during the operative procedure would potentially alter the integrity of the implant shell has attracted legal and medical interest. In this study we therefore investigated whether irrigating breast implants with antimicrobials commonly used in clinical practice with a clinically relevant application time would affect the physical integrity of the implant shell. Materials and methods: Samples, which were previously punched from the shell of explanted standard silicone gel filled breast implants in a defined way, were exposed to different disinfectant solutions for two minutes. Multiple defined specimens from 5 different explants from 4 different producers (including PIP) were tested. The testing included tensile strength and disruption tests. Results: In our prospective test series we could not find a significant influence of a single distinct disinfectant on silicone shell implant surfaces. Conclusion: Despite the potential legal implications that might be considered when a surgeon manipulates an implant with disinfectants intraoperatively, we find it worthwhile to state that from a material and surgical standpoint there is no evidence that short-time treatment of alloplastic materials would be detrimental to the physical properties of the implant shell. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 90(2019)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 90(2019)
- Issue Display:
- Volume 90, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 90
- Issue:
- 2019
- Issue Sort Value:
- 2019-0090-2019-0000
- Page Start:
- 264
- Page End:
- 268
- Publication Date:
- 2019-02
- Subjects:
- Change of mechanical properties -- Disinfectants -- Antibiotics -- Breast silicone implants
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2018.10.021 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9394.xml