Does A Catheter over Needle System Reduce Infusate Leak in Continuous Peripheral Nerve Blockade: A Randomised Controlled Trial. Issue 5 (September 2018)
- Record Type:
- Journal Article
- Title:
- Does A Catheter over Needle System Reduce Infusate Leak in Continuous Peripheral Nerve Blockade: A Randomised Controlled Trial. Issue 5 (September 2018)
- Main Title:
- Does A Catheter over Needle System Reduce Infusate Leak in Continuous Peripheral Nerve Blockade: A Randomised Controlled Trial
- Authors:
- Edwards, R. M.
Currigan, D. A.
Bradbeer, S.
Mitchell, C. - Abstract:
- Continuous peripheral nerve blockade is a common technique in the analgesic management for many procedures. Leakage of local anaesthetic from around the nerve catheter insertion site can increase the chance of catheter dislodgement, risks infective complications, and could divert anaesthetic away from the nerve causing the block to fail. We conducted a randomised controlled trial to assess whether the type of nerve catheter influenced local anaesthetic leak rate. One hundred and ten patients scheduled for elective unilateral total knee arthroplasty were randomised to receive a perineural catheter with either a catheter over needle (CON) system (Pajunk® E-Cath) (PAJUNK® GmbH, Medizintechnologie, Geisingen, Germany), or catheter through needle (CTN) system (Pajunk® SonoLong) (PAJUNK® GmbH, Medizintechnologie, Geisingen, Germany). There was no statistically significant difference in the rate of leaking catheters between groups (CON 1.8% versus CTN 3.7%; P=0.618), however, the overall leak rate was much lower than anticipated from pilot data. The CON system was on average faster to insert (CON 357 seconds versus CTN 482 seconds; P=0.004), but associated with poorer needle visibility under ultrasound (Likert scale 1–5, mean [SD], CON 3.31 [0.96] versus CTN 3.89 [0.84]; P=0.001). All seven instances of inadvertent catheter dislodgement occurred in the CTN group (P=0.006). There was no statistically significant difference between groups in the proportion of patients who hadContinuous peripheral nerve blockade is a common technique in the analgesic management for many procedures. Leakage of local anaesthetic from around the nerve catheter insertion site can increase the chance of catheter dislodgement, risks infective complications, and could divert anaesthetic away from the nerve causing the block to fail. We conducted a randomised controlled trial to assess whether the type of nerve catheter influenced local anaesthetic leak rate. One hundred and ten patients scheduled for elective unilateral total knee arthroplasty were randomised to receive a perineural catheter with either a catheter over needle (CON) system (Pajunk® E-Cath) (PAJUNK® GmbH, Medizintechnologie, Geisingen, Germany), or catheter through needle (CTN) system (Pajunk® SonoLong) (PAJUNK® GmbH, Medizintechnologie, Geisingen, Germany). There was no statistically significant difference in the rate of leaking catheters between groups (CON 1.8% versus CTN 3.7%; P=0.618), however, the overall leak rate was much lower than anticipated from pilot data. The CON system was on average faster to insert (CON 357 seconds versus CTN 482 seconds; P=0.004), but associated with poorer needle visibility under ultrasound (Likert scale 1–5, mean [SD], CON 3.31 [0.96] versus CTN 3.89 [0.84]; P=0.001). All seven instances of inadvertent catheter dislodgement occurred in the CTN group (P=0.006). There was no statistically significant difference between groups in the proportion of patients who had adequate analgesia on day one (CON 80% versus CTN 86.5%; P=0.294) and day two postoperatively (CON 85.5% versus CTN 91.8%; P=0.369). Our findings show the overall leak rate to be very low with both catheter systems; however, the CON system may have advantages in terms of speed of use and rate of inadvertent catheter dislodgement. … (more)
- Is Part Of:
- Anaesthesia and intensive care. Volume 46:Issue 5(2018)
- Journal:
- Anaesthesia and intensive care
- Issue:
- Volume 46:Issue 5(2018)
- Issue Display:
- Volume 46, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 5
- Issue Sort Value:
- 2018-0046-0005-0000
- Page Start:
- 468
- Page End:
- 473
- Publication Date:
- 2018-09
- Subjects:
- continuous nerve block -- regional anaesthesia -- anaesthesia: complications -- total knee arthroplasty
Anesthesiology -- Periodicals
Intensive Care Units -- Periodicals
617.96 - Journal URLs:
- https://journals.sagepub.com/home/aic ↗
- DOI:
- 10.1177/0310057X1804600507 ↗
- Languages:
- English
- ISSNs:
- 0310-057X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 9402.xml