The potential effects of introducing microneedle patch vaccines into routine vaccine supply chains. Issue 4 (21st January 2019)
- Record Type:
- Journal Article
- Title:
- The potential effects of introducing microneedle patch vaccines into routine vaccine supply chains. Issue 4 (21st January 2019)
- Main Title:
- The potential effects of introducing microneedle patch vaccines into routine vaccine supply chains
- Authors:
- Wedlock, Patrick T.
Mitgang, Elizabeth A.
Elsheikh, Fayad
Leonard, Jim
Bakal, Jenn
Welling, Joel
Crawford, Jessica
Assy, Emmanuelle
Magadzire, Bvudzai P.
Bechtel, Ruth
DePasse, Jay V.
Siegmund, Sheryl S.
Brown, Shawn T.
Lee, Bruce Y. - Abstract:
- Abstract: Background: Microneedle patch (MNP) technology is designed to simplify the process of vaccine administration; however, depending on its characteristics, MNP technology may provide additional benefits beyond the point-of-use, particularly for vaccine supply chains. Methods: Using the HERMES modeling software, we examined replacing four routine vaccines – Measles-containing vaccine (MCV), Tetanus toxoid (TT), Rotavirus (Rota) and Pentavalent (Penta) – with MNP versions in the routine vaccine supply chains of Benin, Bihar (India), and Mozambique. Results: Replacing MCV with an MNP (5 cm 3 -per-dose, 2-month thermostability, current single-dose price-per-dose) improved MCV availability by 13%, 1% and 6% in Benin, Bihar and Mozambique, respectively, and total vaccine availability by 1% in Benin and Mozambique, while increasing the total cost per dose administered by $0.07 in Benin, $0.56 in Bihar and $0.11 in Mozambique. Replacing TT with an MNP improved TT and total vaccine availability (3% and <1%) in Mozambique only, when the patch was 5 cm 3 and 2-months thermostable but increased total cost per dose administered by $0.14. Replacing Rota with an MNP (at 5–15 cm 3 -per-dose, 1–2 month thermostable) improved Rota and total vaccine availability, but only improved Rota vaccine availability in Bihar (at 5 cm 3, 1–2 months thermostable), while decreasing total vaccine availability by 1%. Finally, replacing Penta with an MNP (at 5 cm 3, 2-months thermostable) improvedAbstract: Background: Microneedle patch (MNP) technology is designed to simplify the process of vaccine administration; however, depending on its characteristics, MNP technology may provide additional benefits beyond the point-of-use, particularly for vaccine supply chains. Methods: Using the HERMES modeling software, we examined replacing four routine vaccines – Measles-containing vaccine (MCV), Tetanus toxoid (TT), Rotavirus (Rota) and Pentavalent (Penta) – with MNP versions in the routine vaccine supply chains of Benin, Bihar (India), and Mozambique. Results: Replacing MCV with an MNP (5 cm 3 -per-dose, 2-month thermostability, current single-dose price-per-dose) improved MCV availability by 13%, 1% and 6% in Benin, Bihar and Mozambique, respectively, and total vaccine availability by 1% in Benin and Mozambique, while increasing the total cost per dose administered by $0.07 in Benin, $0.56 in Bihar and $0.11 in Mozambique. Replacing TT with an MNP improved TT and total vaccine availability (3% and <1%) in Mozambique only, when the patch was 5 cm 3 and 2-months thermostable but increased total cost per dose administered by $0.14. Replacing Rota with an MNP (at 5–15 cm 3 -per-dose, 1–2 month thermostable) improved Rota and total vaccine availability, but only improved Rota vaccine availability in Bihar (at 5 cm 3, 1–2 months thermostable), while decreasing total vaccine availability by 1%. Finally, replacing Penta with an MNP (at 5 cm 3, 2-months thermostable) improved Penta vaccine availability by 1–8% and total availability by <1–9%. Conclusions: An MNP for MCV, TT, Rota, or Penta would need to have a smaller or equal volume-per-dose than existing vaccine formulations and be able to be stored outside the cold chain for a continuous period of at least two months to provide additional benefits to all three supply chains under modeled conditions. … (more)
- Is Part Of:
- Vaccine. Volume 37:Issue 4(2019)
- Journal:
- Vaccine
- Issue:
- Volume 37:Issue 4(2019)
- Issue Display:
- Volume 37, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 37
- Issue:
- 4
- Issue Sort Value:
- 2019-0037-0004-0000
- Page Start:
- 645
- Page End:
- 651
- Publication Date:
- 2019-01-21
- Subjects:
- Delivery -- Logistics -- Microneedle patch -- Supply chain
Vaccines -- Periodicals
615.372 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0264410X ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0264410X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0264410X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.vaccine.2018.12.008 ↗
- Languages:
- English
- ISSNs:
- 0264-410X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9138.628000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9372.xml