Eligibility for subcutaneous implantable cardioverter defibrillators in the adult congenital heart disease population. Issue 1 (4th December 2018)
- Record Type:
- Journal Article
- Title:
- Eligibility for subcutaneous implantable cardioverter defibrillators in the adult congenital heart disease population. Issue 1 (4th December 2018)
- Main Title:
- Eligibility for subcutaneous implantable cardioverter defibrillators in the adult congenital heart disease population
- Authors:
- Garside, Hannah
Leyva, Francisco
Hudsmith, Lucy
Marshall, Howard
de Bono, Joseph - Abstract:
- Abstract: Background: Patients with adult congenital heart disease (ACHD) have an increased risk of arrhythmic and sudden cardiac death. The subcutaneous implantable cardioverter defibrillator (S‐ICD) provides a potentially safer alternative to transvenous ICDs in ACHD. Suitability for S‐ICD depends on the surface electrocardiogram (ECG), which is often abnormal in ACHD patients. This study investigates the proportion of ACHD patients who meet the screening criteria for S‐ICD implantation. Methods: A standard screening ECG was performed in 102 patients with complex ACHD (Tetralogy of Fallot, Fontan circulation, and transposition of the great arteries). This process was repeated postexercise for patients who also had an exercise test. Results: Three quarters (75.4%) of ACHD patients meet screening criteria for an S‐ICD with at least one suitable vector. The most common number of acceptable vectors in the eligible group was two (35% of total population). In only 12% of total population, all three vectors were suitable while only one vector was suitable in 28% of total population. The primary vector (equivalent of ECG lead III) was the most common suitable vector, found in 62% of participants who had appropriate sensing vectors. Twenty‐five (24.5%) patients failed to meet the S‐ICD screening criteria. Of these, 14 had repaired tetralogy of Fallot. A total of 92% of patients with a Fontan circulation met ECG screening criteria. Of those who had the protocol repeated followingAbstract: Background: Patients with adult congenital heart disease (ACHD) have an increased risk of arrhythmic and sudden cardiac death. The subcutaneous implantable cardioverter defibrillator (S‐ICD) provides a potentially safer alternative to transvenous ICDs in ACHD. Suitability for S‐ICD depends on the surface electrocardiogram (ECG), which is often abnormal in ACHD patients. This study investigates the proportion of ACHD patients who meet the screening criteria for S‐ICD implantation. Methods: A standard screening ECG was performed in 102 patients with complex ACHD (Tetralogy of Fallot, Fontan circulation, and transposition of the great arteries). This process was repeated postexercise for patients who also had an exercise test. Results: Three quarters (75.4%) of ACHD patients meet screening criteria for an S‐ICD with at least one suitable vector. The most common number of acceptable vectors in the eligible group was two (35% of total population). In only 12% of total population, all three vectors were suitable while only one vector was suitable in 28% of total population. The primary vector (equivalent of ECG lead III) was the most common suitable vector, found in 62% of participants who had appropriate sensing vectors. Twenty‐five (24.5%) patients failed to meet the S‐ICD screening criteria. Of these, 14 had repaired tetralogy of Fallot. A total of 92% of patients with a Fontan circulation met ECG screening criteria. Of those who had the protocol repeated following their cardiopulmonary exercise test ( n = 14), only one additional patient failed to meet the eligibility criteria. Conclusions: A quarter of ACHD patients do not meet the eligibility criteria for the S‐ICD. However, more than 90% of patients with a Fontan circulation are suitable for an S‐ICD. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 1(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 1(2019)
- Issue Display:
- Volume 42, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2019-0042-0001-0000
- Page Start:
- 65
- Page End:
- 70
- Publication Date:
- 2018-12-04
- Subjects:
- adult congenital heart disease -- Fontan circulation -- subcutaneous implantable cardioverter defibrillator -- tetralogy of Fallot
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13537 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9375.xml