Label‐Free Bioanalysis Based on Low‐Q Whispering Gallery Modes: Rapid Preparation of Microsensors by Means of Layer‐by‐Layer Technology. (20th November 2018)
- Record Type:
- Journal Article
- Title:
- Label‐Free Bioanalysis Based on Low‐Q Whispering Gallery Modes: Rapid Preparation of Microsensors by Means of Layer‐by‐Layer Technology. (20th November 2018)
- Main Title:
- Label‐Free Bioanalysis Based on Low‐Q Whispering Gallery Modes: Rapid Preparation of Microsensors by Means of Layer‐by‐Layer Technology
- Authors:
- Olszyna, Mateusz
Debrassi, Aline
Üzüm, Cagri
Dähne, Lars - Abstract:
- Abstract: Low‐Q‐whispering gallery modes (low‐Q‐WGM) can be used for label‐free detection of interactions between biomolecules, measuring their binding and release kinetics or for analysis of changes in the medium in real‐time. The main advantage of the low‐Q‐WGM approach over other label‐free methods is the possibility of measurements in small cavities as the method uses microparticles down to 6 µm as sensors. Commercially available dye‐doped microparticles that are used as low‐Q‐WGM sensors exhibit several drawbacks. Therefore, alternative particle types are developed and optimized as low‐Q‐WGM sensors. First, dye‐doped particles made of different materials are screened. The most critical parameter for WGM performance is the refractive index (RI) of sensor particles. Furthermore, surface roughness of particles, determined by scanning electron microscopy and atomic force microscopy, affects their performance as WGM microsensors. In the second test, fluorescent dyes immobilized on nonfluorescent particles by means of nanometer thick layer‐by‐layer (LbL) films are shown to generate a strong WGM signal. The LbL‐coated particles show remarkably less background fluorescence than dye‐doped particles and are easier to prepare. Finally, this article proposes rapid preparation methods for WGM microparticle sensors based on various parameters such as material type, RI, surface roughness, and number of coated polymer layers. Abstract : A new method for the preparation of fluorescentAbstract: Low‐Q‐whispering gallery modes (low‐Q‐WGM) can be used for label‐free detection of interactions between biomolecules, measuring their binding and release kinetics or for analysis of changes in the medium in real‐time. The main advantage of the low‐Q‐WGM approach over other label‐free methods is the possibility of measurements in small cavities as the method uses microparticles down to 6 µm as sensors. Commercially available dye‐doped microparticles that are used as low‐Q‐WGM sensors exhibit several drawbacks. Therefore, alternative particle types are developed and optimized as low‐Q‐WGM sensors. First, dye‐doped particles made of different materials are screened. The most critical parameter for WGM performance is the refractive index (RI) of sensor particles. Furthermore, surface roughness of particles, determined by scanning electron microscopy and atomic force microscopy, affects their performance as WGM microsensors. In the second test, fluorescent dyes immobilized on nonfluorescent particles by means of nanometer thick layer‐by‐layer (LbL) films are shown to generate a strong WGM signal. The LbL‐coated particles show remarkably less background fluorescence than dye‐doped particles and are easier to prepare. Finally, this article proposes rapid preparation methods for WGM microparticle sensors based on various parameters such as material type, RI, surface roughness, and number of coated polymer layers. Abstract : A new method for the preparation of fluorescent low‐Q‐whispering gallery mode (low‐Q‐WGM) microsensors is proposed . The fluorescent dye is immobilized on the surface of spherical particle by means of layer‐by‐layer (LbL) coating with a labeled, thin nanometer polymer film. The LbL‐fluorescent low‐Q‐WGM beads are more versatile, easier in (bio‐) functionalization, and show a significantly higher signal/background ratio than dye‐doped beads. … (more)
- Is Part Of:
- Advanced functional materials. Volume 29:Number 2(2019)
- Journal:
- Advanced functional materials
- Issue:
- Volume 29:Number 2(2019)
- Issue Display:
- Volume 29, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2019-0029-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-11-20
- Subjects:
- fluorescent microparticles -- label‐free bioanalytics -- layer‐by‐layer coating -- whispering gallery mode
Materials -- Periodicals
Chemical vapor deposition -- Periodicals
620.11 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1616-3028 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/adfm.201805998 ↗
- Languages:
- English
- ISSNs:
- 1616-301X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0696.853900
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9373.xml