Study of biodegradable occluder of atrial septal defect in a porcine model. Issue 1 (9th September 2018)
- Record Type:
- Journal Article
- Title:
- Study of biodegradable occluder of atrial septal defect in a porcine model. Issue 1 (9th September 2018)
- Main Title:
- Study of biodegradable occluder of atrial septal defect in a porcine model
- Authors:
- Li, Bo‐Ning
Xie, Yu‐Mei
Xie, Zhao‐Feng
Chen, Xian‐Miao
Zhang, Gui
Zhang, De‐Yuan
Liu, Xiang‐Dong
Zhang, Zhi‐Wei - Abstract:
- Abstract: Objective: To evaluate the safety and feasibility of a modified poly(l ‐lactic acid) (PLLA) atrial septal defect (ASD) occluder. Methods: Forty‐five piglets were divided into two groups: an experimental group ( n = 27) and a control group ( n = 18). The experimental group underwent percutaneous implantation of a modified PLLA ASD device while the control group underwent percutaneous implantation of a widely used metal ASD device. X‐ray imaging, transthoracic echocardiography (TTE), electrocardiogram (ECG), histopathology and electron microscopic examination were performed at 7 days, 1, 3, 6, and 12 months after implantation. Results: Twenty‐seven experimental piglets and 18 control piglets were all successfully implanted with modified biodegradable and metal ASD devices, respectively. While both devices exhibited very good occluding effects, the modified PLLA ASD devices were completely endothelialized at 3 months after implantation, and the endothelialization appeared to be more complete compared to the control group. Degradation of the PLLA devices was noted at 12 months follow‐up with no loss of integrity at the atrial septum. Conclusion: This animal model with implanting of the occluders was effective and not associated with complications. The modified PLLA ASD devices are more controllable and practical than our previous devices. The implanted devices demonstrated good endothelialization and degradability in short and moderate term follow‐up. Long‐termAbstract: Objective: To evaluate the safety and feasibility of a modified poly(l ‐lactic acid) (PLLA) atrial septal defect (ASD) occluder. Methods: Forty‐five piglets were divided into two groups: an experimental group ( n = 27) and a control group ( n = 18). The experimental group underwent percutaneous implantation of a modified PLLA ASD device while the control group underwent percutaneous implantation of a widely used metal ASD device. X‐ray imaging, transthoracic echocardiography (TTE), electrocardiogram (ECG), histopathology and electron microscopic examination were performed at 7 days, 1, 3, 6, and 12 months after implantation. Results: Twenty‐seven experimental piglets and 18 control piglets were all successfully implanted with modified biodegradable and metal ASD devices, respectively. While both devices exhibited very good occluding effects, the modified PLLA ASD devices were completely endothelialized at 3 months after implantation, and the endothelialization appeared to be more complete compared to the control group. Degradation of the PLLA devices was noted at 12 months follow‐up with no loss of integrity at the atrial septum. Conclusion: This animal model with implanting of the occluders was effective and not associated with complications. The modified PLLA ASD devices are more controllable and practical than our previous devices. The implanted devices demonstrated good endothelialization and degradability in short and moderate term follow‐up. Long‐term studies are now underway to further evaluate the biodegradability of this novel device. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 93:Issue 1(2019)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 93:Issue 1(2019)
- Issue Display:
- Volume 93, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 93
- Issue:
- 1
- Issue Sort Value:
- 2019-0093-0001-0000
- Page Start:
- E38
- Page End:
- E45
- Publication Date:
- 2018-09-09
- Subjects:
- atrial septal defect -- biodegradable occluder -- congenital heart disease -- endothelialization -- poly(l‐lactic acid)
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.27852 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9370.xml