Clinically insignificant trunnionosis in large-diameter metal-on-polyethylene total hip arthroplasty. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- Clinically insignificant trunnionosis in large-diameter metal-on-polyethylene total hip arthroplasty. Issue 1 (January 2017)
- Main Title:
- Clinically insignificant trunnionosis in large-diameter metal-on-polyethylene total hip arthroplasty
- Authors:
- Hothi, H. S.
Kendoff, D.
Lausmann, C.
Henckel, J.
Gehrke, T.
Skinner, J.
Hart, A. - Abstract:
- Abstract : Objectives: Mechanical wear and corrosion at the head-stem junction of total hip arthroplasties (THAs) (trunnionosis) have been implicated in their early revision, most commonly in metal-on-metal (MOM) hips. We can isolate the role of the head-stem junction as the predominant source of metal release by investigating non-MOM hips; this can help to identify clinically significant volumes of material loss and corrosion from these surfaces. Methods: In this study we examined a series of 94 retrieved metal-on-polyethylene (MOP) hips for evidence of corrosion and material loss at the taper junction using a well published visual grading method and an established roundness-measuring machine protocol. Hips were retrieved from 74 male and 20 female patients with a median age of 57 years (30 to 76) and a median time to revision of 215 months (2 to 324). The reasons for revision were loosening of both the acetabular component and the stem (n = 29), loosening of the acetabular component (n = 58) and infection (n = 7). No adverse tissue reactions were reported by the revision surgeons. Results: Evidence of corrosion was observed in 55% of hips. The median Goldberg taper corrosion score was 2 (1 to 4) and the annual rate of material loss at the taper was 0.084 mm 3 /year (0 to 0.239). The median trunnion corrosion score was 1 (1 to 3). Conclusions: We have reported a level of trunnionosis for MOP hips with large-diameter heads that were revised for reasons other thanAbstract : Objectives: Mechanical wear and corrosion at the head-stem junction of total hip arthroplasties (THAs) (trunnionosis) have been implicated in their early revision, most commonly in metal-on-metal (MOM) hips. We can isolate the role of the head-stem junction as the predominant source of metal release by investigating non-MOM hips; this can help to identify clinically significant volumes of material loss and corrosion from these surfaces. Methods: In this study we examined a series of 94 retrieved metal-on-polyethylene (MOP) hips for evidence of corrosion and material loss at the taper junction using a well published visual grading method and an established roundness-measuring machine protocol. Hips were retrieved from 74 male and 20 female patients with a median age of 57 years (30 to 76) and a median time to revision of 215 months (2 to 324). The reasons for revision were loosening of both the acetabular component and the stem (n = 29), loosening of the acetabular component (n = 58) and infection (n = 7). No adverse tissue reactions were reported by the revision surgeons. Results: Evidence of corrosion was observed in 55% of hips. The median Goldberg taper corrosion score was 2 (1 to 4) and the annual rate of material loss at the taper was 0.084 mm 3 /year (0 to 0.239). The median trunnion corrosion score was 1 (1 to 3). Conclusions: We have reported a level of trunnionosis for MOP hips with large-diameter heads that were revised for reasons other than trunnionosis, and therefore may be clinically insignificant. Cite this article : H. S. Hothi, D. Kendoff, C. Lausmann, J. Henckel, T. Gehrke, J. Skinner, A. Hart. Clinically insignificant trunnionosis in large-diameter metal-on-polyethylene total hip arthroplasty. Bone Joint Res 2017;6:52–56. DOI: 10.1302/2046-3758.61.BJR-2016-0150.R2. … (more)
- Is Part Of:
- Bone & joint research. Volume 6:Issue 1(2017)
- Journal:
- Bone & joint research
- Issue:
- Volume 6:Issue 1(2017)
- Issue Display:
- Volume 6, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 6
- Issue:
- 1
- Issue Sort Value:
- 2017-0006-0001-0000
- Page Start:
- 52
- Page End:
- 56
- Publication Date:
- 2017-01
- Subjects:
- Taper -- Corrosion -- Wear -- Hip -- Metal-on-polyethylene
Musculoskeletal system -- Periodicals
573.705 - Journal URLs:
- http://www.bjr.boneandjoint.org.uk/ ↗
- DOI:
- 10.1302/2046-3758.61.BJR-2016-0150.R2 ↗
- Languages:
- English
- ISSNs:
- 2046-3758
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 9362.xml