Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study. Issue 9 (7th August 2015)
- Record Type:
- Journal Article
- Title:
- Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study. Issue 9 (7th August 2015)
- Main Title:
- Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study
- Authors:
- Thor, Daniel
Brismar, Torkel B.
Fischer, Michael A. - Abstract:
- Abstract : Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast‐to‐noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m 2 with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64‐slice DS‐CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m 2 ) and for all sizes (16–35 kg/m 2 ) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual‐energy CT allowsAbstract : Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast‐to‐noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m 2 with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64‐slice DS‐CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m 2 ) and for all sizes (16–35 kg/m 2 ) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual‐energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 9(2015)
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 9(2015)
- Issue Display:
- Volume 42, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 9
- Issue Sort Value:
- 2015-0042-0009-0000
- Page Start:
- 5100
- Page End:
- 5109
- Publication Date:
- 2015-08-07
- Subjects:
- biological tissues -- computerised tomography -- dosimetry -- medical image processing -- phantoms
Computed tomography -- Dosimetry/exposure assessment
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Scintigraphy
computed tomography -- contrast media reduction -- low kilovoltage -- dual source -- dual energy
Medical image noise -- Computed tomography -- Medical image contrast -- Soft X‐rays -- Tissues -- High voltage direct current transmission -- Medical X‐ray imaging -- X‐ray scattering
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4927791 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9358.xml