Prospective Randomized Evaluation of Implantable Cardioverter‐Defibrillator Programming in Patients With a Left Ventricular Assist Device. Issue 5 (23rd February 2018)
- Record Type:
- Journal Article
- Title:
- Prospective Randomized Evaluation of Implantable Cardioverter‐Defibrillator Programming in Patients With a Left Ventricular Assist Device. Issue 5 (23rd February 2018)
- Main Title:
- Prospective Randomized Evaluation of Implantable Cardioverter‐Defibrillator Programming in Patients With a Left Ventricular Assist Device
- Authors:
- Richardson, Travis D.
Hale, Leslie
Arteaga, Christopher
Xu, Meng
Keebler, Mary
Schlendorf, Kelly
Danter, Matthew
Shah, Ashish
Lindenfeld, JoAnn
Ellis, Christopher R. - Abstract:
- Abstract : Background: Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy‐programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra‐conservative ICD programming strategy in patients with LVAD affects ICD shocks. Methods and Results: Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra‐conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra‐conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT‐ON but this was not statistically significant: 10% of patients with CRT‐ON (n=21) versus 38% withAbstract : Background: Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy‐programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra‐conservative ICD programming strategy in patients with LVAD affects ICD shocks. Methods and Results: Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra‐conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra‐conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT‐ON but this was not statistically significant: 10% of patients with CRT‐ON (n=21) versus 38% with CRT‐OFF (n=20) received shocks ( P =0.08). Conclusions: An ultra‐conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. Clinical Trial Registration: URL:https://www.clinicaltrials.gov . Unique identifier: NCT01977703. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 7:Issue 5(2018)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 7:Issue 5(2018)
- Issue Display:
- Volume 7, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 5
- Issue Sort Value:
- 2018-0007-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-02-23
- Subjects:
- cardiac resynchronization therapy -- implantable cardioverter defibrillator -- left ventricular assist device
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.117.007748 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9363.xml