Noise reduction for curve‐linear structures in real time fluoroscopy applications using directional binary masks. Issue 8 (14th July 2015)
- Record Type:
- Journal Article
- Title:
- Noise reduction for curve‐linear structures in real time fluoroscopy applications using directional binary masks. Issue 8 (14th July 2015)
- Main Title:
- Noise reduction for curve‐linear structures in real time fluoroscopy applications using directional binary masks
- Authors:
- Wagner, Martin
Yang, Pengfei
Schafer, Sebastian
Strother, Charles
Mistretta, Charles - Abstract:
- Abstract : Purpose: Recent efforts in the reconstruction of interventional devices from two distinct views require the segmentation of the object in both fluoroscopic images. Noise might decrease the quality of the segmentation and cause artifacts in the reconstruction. The noise level depends on the x‐ray dose the patient is exposed to. The proposed algorithm reduces the noise and enhances the separability of curvilinear devices in background subtracted fluoroscopic images to allow a more accurate segmentation. Methods: The algorithm uses a set of binary masks to estimate a line conformity measure that determines the best direction for a directional filter kernel. If the calculated value exceeds a certain threshold, the directional kernel is used to obtain the filtered value. Otherwise, an isotropic filter kernel is used. Results: The evaluation was performed on a set of 36 fluoroscopic images using a vascular head phantom with three different guidewires and nine different x‐ray dosages from 6 nGy/pulse to 45 nGy/pulse as well as a clinical data set containing ten images. Compared with wavelet shrinkage and the bilateral filter, the proposed algorithm increased the average contrast to noise ratio by at least 17.8% for the phantom and 68.9% for the clinical images. The accuracy of the device segmentation was improved on average by at least 17.3% and 14.0%, respectively. Conclusions: The proposed algorithm was able to significantly reduce the amount of noise in the images andAbstract : Purpose: Recent efforts in the reconstruction of interventional devices from two distinct views require the segmentation of the object in both fluoroscopic images. Noise might decrease the quality of the segmentation and cause artifacts in the reconstruction. The noise level depends on the x‐ray dose the patient is exposed to. The proposed algorithm reduces the noise and enhances the separability of curvilinear devices in background subtracted fluoroscopic images to allow a more accurate segmentation. Methods: The algorithm uses a set of binary masks to estimate a line conformity measure that determines the best direction for a directional filter kernel. If the calculated value exceeds a certain threshold, the directional kernel is used to obtain the filtered value. Otherwise, an isotropic filter kernel is used. Results: The evaluation was performed on a set of 36 fluoroscopic images using a vascular head phantom with three different guidewires and nine different x‐ray dosages from 6 nGy/pulse to 45 nGy/pulse as well as a clinical data set containing ten images. Compared with wavelet shrinkage and the bilateral filter, the proposed algorithm increased the average contrast to noise ratio by at least 17.8% for the phantom and 68.9% for the clinical images. The accuracy of the device segmentation was improved on average by at least 17.3% and 14.0%, respectively. Conclusions: The proposed algorithm was able to significantly reduce the amount of noise in the images and therefore increase the quality of the device segmentations compared to both the bilateral filter and the wavelet thresholding approach for all acquired noise levels using rotating directional filter kernels near line structures and isotropic kernels for the background. The application of the proposed algorithm for the 3D reconstruction of curvilinear devices from two views would allow a more accurate reconstruction of the device. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 8(2015)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 8(2015)Part 1
- Issue Display:
- Volume 42, Issue 8, Part 1 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2015-0042-0008-0001
- Page Start:
- 4645
- Page End:
- 4653
- Publication Date:
- 2015-07-14
- Subjects:
- diagnostic radiography -- dosimetry -- filtering theory -- image denoising -- image enhancement -- image reconstruction -- image segmentation -- medical image processing -- phantoms
Radiography -- Dosimetry/exposure assessment -- Noise -- Reconstruction -- Segmentation -- Edge enhancement
Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Image enhancement or restoration, e.g. from bit‐mapped to bit‐mapped creating a similar image -- Scintigraphy
noise reduction -- segmentation -- fluoroscopy -- binary masks
Medical image noise -- Medical image segmentation -- Wavelets -- Medical X‐ray imaging -- Machinery noise -- Noise propagation -- X‐ray imaging -- Medical image contrast
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4924266 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9357.xml