Accurate assessment and prediction of noise in clinical CT images. Issue 1 (31st December 2015)
- Record Type:
- Journal Article
- Title:
- Accurate assessment and prediction of noise in clinical CT images. Issue 1 (31st December 2015)
- Main Title:
- Accurate assessment and prediction of noise in clinical CT images
- Authors:
- Tian, Xiaoyu
Samei, Ehsan - Abstract:
- Abstract : Purpose: The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. Methods: The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose levels). The quantum noise in clinical images was measured by subtracting sequential slices and filtering out edges. Noise was then measured in the resultant uniform area. The noise measurement technique was validated using 17 clinical image cases and a turkey phantom. With a validated method to measure noise in clinical images, this noise was predicted by establishing the correlation between water‐equivalent diameter (Dw) and noise in a variable‐sized phantom and ascribing a noise level to the patient based on Dw estimated from CT image. The accuracy of this prediction model was validated using 66 clinical image sets. Results: The error in noise measurement was within 1.5 HU across two reconstruction algorithms. In terms of noise prediction, across the 83 clinical image sets, the average discrepancies between predicted and measured noise were 6.9% and 6.6% for adaptive statistical iterative reconstruction and filtered back projection reconstruction, respectively. Conclusions: This study proposed a practically applicable method to assess quantum noise in clinical images. The image‐based measurement technique enables automatic quality controlAbstract : Purpose: The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. Methods: The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose levels). The quantum noise in clinical images was measured by subtracting sequential slices and filtering out edges. Noise was then measured in the resultant uniform area. The noise measurement technique was validated using 17 clinical image cases and a turkey phantom. With a validated method to measure noise in clinical images, this noise was predicted by establishing the correlation between water‐equivalent diameter (Dw) and noise in a variable‐sized phantom and ascribing a noise level to the patient based on Dw estimated from CT image. The accuracy of this prediction model was validated using 66 clinical image sets. Results: The error in noise measurement was within 1.5 HU across two reconstruction algorithms. In terms of noise prediction, across the 83 clinical image sets, the average discrepancies between predicted and measured noise were 6.9% and 6.6% for adaptive statistical iterative reconstruction and filtered back projection reconstruction, respectively. Conclusions: This study proposed a practically applicable method to assess quantum noise in clinical images. The image‐based measurement technique enables automatic quality control monitoring of image noise in clinical practice. Further, a phantom‐based model can accurately predict quantum noise level in patient images. The prediction model can be used to quantitatively optimize individual protocol to achieve targeted noise level in clinical images. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 1(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 1(2016)
- Issue Display:
- Volume 43, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 1
- Issue Sort Value:
- 2016-0043-0001-0000
- Page Start:
- 475
- Page End:
- 482
- Publication Date:
- 2015-12-31
- Subjects:
- computerised tomography -- image reconstruction -- medical image processing -- phantoms
Computed tomography -- Reconstruction
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general
medical imaging -- computed tomography -- image quality -- noise -- image‐based
Medical image noise -- Computed tomography -- Quantum noise -- Medical image reconstruction -- Quantum measurement theory -- Image quality assessment -- Image scanners -- Lungs
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4938588 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9339.xml