Impact of ganglionated plexi ablation on high‐frequency stimulation‐induced changes in atrial fibrillation cycle length in the pulmonary vein. Issue 5 (18th September 2013)
- Record Type:
- Journal Article
- Title:
- Impact of ganglionated plexi ablation on high‐frequency stimulation‐induced changes in atrial fibrillation cycle length in the pulmonary vein. Issue 5 (18th September 2013)
- Main Title:
- Impact of ganglionated plexi ablation on high‐frequency stimulation‐induced changes in atrial fibrillation cycle length in the pulmonary vein
- Authors:
- Takami, Mitsuru
Yamashiro, Kohei
Sakamoto, Yuichiro
Satoh, Koyo
Suzuki, Takahiko - Abstract:
- Abstract: Background: We assessed high‐frequency stimulation (HFS)‐induced changes in the atrial fibrillation (AF) cycle length (AFCL) in the pulmonary vein (PV) after ganglionated plexi (GP) ablation. Methods: Twenty‐two patients undergoing catheter ablation for AF were retrospectively enrolled. Sites showing a vagal response (VR) to HFS were defined as GP‐positive sites. AFCL was determined in the adjacent PV, distant PV, coronary sinus, and right atrium. Twenty cycles were counted before and after each HFS. After radiofrequency application to the GP site, HFS was repeated. Results: At GP‐positive sites ( n =57), significant shortening of the AFCL was detected in the adjacent PV (17% shortening, 165±38 to 137±27 ms, p <0.001) and distant PV (4.8% shortening, p <0.001), but not in the coronary sinus (0.8% shortening, p =0.27) or right atrium (1.8% shortening, p =0.06). However, no significant shortening was observed at GP‐negative sites ( n =25). At 41 of the 57 sites where VR disappeared after a single radiofrequency application, no significant shortening was observed in the adjacent PV (2.1% shortening, p =0.25). At 16 of the 57 sites where VR was still present, significant shortening was observed in the adjacent PV (16% shortening, p <0.001). Conclusions: HFS of the GP has a strong influence on AFCL in the PV.
- Is Part Of:
- Journal of arrhythmia. Volume 30:Issue 5(2014)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 30:Issue 5(2014)
- Issue Display:
- Volume 30, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2014-0030-0005-0000
- Page Start:
- 356
- Page End:
- 361
- Publication Date:
- 2013-09-18
- Subjects:
- Atrial fibrillation -- Ganglionated plexi -- Pulmonary vein -- Firing -- High‐frequency stimulation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2013.07.008 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9341.xml