An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features. Issue 5 (12th April 2017)
- Record Type:
- Journal Article
- Title:
- An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features. Issue 5 (12th April 2017)
- Main Title:
- An effective noise reduction method for multi‐energy CT images that exploit spatio‐spectral features
- Authors:
- Li, Zhoubo
Leng, Shuai
Yu, Lifeng
Manduca, Armando
McCollough, Cynthia H. - Abstract:
- Abstract : Purpose: To develop and evaluate an image‐domain noise reduction method for multi‐energy CT (MECT) data. Methods: Multi‐Energy Non‐Local Means (MENLM) is a technique that uses the redundant information in MECT images to achieve noise reduction. In this method, spatio‐spectral features are used to determine the similarity between pixels, making the similarity evaluation more robust to image noise. The performance of this MENLM filter was tested on images acquired on a whole‐body research photon counting CT system. The impact of filtering on image quality was quantitatively evaluated in phantom studies in terms of image noise level (standard deviation of pixel values), noise power spectrum (NPS), in‐plane and cross‐plane spatial resolution, CT number accuracy, material decomposition performance, and subjective low‐contrast spatial resolution using the American College of Radiology (ACR) CT accreditation phantom. Clinical feasibility was assessed by performing MENLM on contrast‐enhanced swine images and unenhanced cadaver head images using clinically relevant doses and dose rates. Results: The phantom studies demonstrated that the MENLM filter reduced noise substantially and still preserved the shape and peak frequency of the NPS. With 80% noise reduction, MENLM filtering caused no degradation of high‐contrast spatial resolution, as illustrated by the modulation transfer function (MTF) and slice sensitivity profile (SSP). CT number accuracy was also maintained forAbstract : Purpose: To develop and evaluate an image‐domain noise reduction method for multi‐energy CT (MECT) data. Methods: Multi‐Energy Non‐Local Means (MENLM) is a technique that uses the redundant information in MECT images to achieve noise reduction. In this method, spatio‐spectral features are used to determine the similarity between pixels, making the similarity evaluation more robust to image noise. The performance of this MENLM filter was tested on images acquired on a whole‐body research photon counting CT system. The impact of filtering on image quality was quantitatively evaluated in phantom studies in terms of image noise level (standard deviation of pixel values), noise power spectrum (NPS), in‐plane and cross‐plane spatial resolution, CT number accuracy, material decomposition performance, and subjective low‐contrast spatial resolution using the American College of Radiology (ACR) CT accreditation phantom. Clinical feasibility was assessed by performing MENLM on contrast‐enhanced swine images and unenhanced cadaver head images using clinically relevant doses and dose rates. Results: The phantom studies demonstrated that the MENLM filter reduced noise substantially and still preserved the shape and peak frequency of the NPS. With 80% noise reduction, MENLM filtering caused no degradation of high‐contrast spatial resolution, as illustrated by the modulation transfer function (MTF) and slice sensitivity profile (SSP). CT number accuracy was also maintained for all energy channels, demonstrating that energy resolution was not affected by filtering. Material decomposition performance was improved with MENLM filtering. The subjective evaluation using the ACR phantom demonstrated an improvement in low‐contrast performance. MENLM achieved effective noise reduction in both contrast‐enhanced swine images and unenhanced cadaver head images, resulting in improved detection of subtle vascular structures and the differentiation of white/gray matter. Conclusion: In MECT, MENLM achieved around 80% noise reduction and greatly improved material decomposition performance and the detection of subtle anatomical/low‐contrast features while maintaining spatial and energy resolution. MENLM filtering may improve diagnostic or functional analysis accuracy and facilitate radiation dose and contrast media reduction for MECT. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 5(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 5(2017)
- Issue Display:
- Volume 44, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2017-0044-0005-0000
- Page Start:
- 1610
- Page End:
- 1623
- Publication Date:
- 2017-04-12
- Subjects:
- CT dose reduction -- image denoising -- multi‐energy CT -- non‐local means filtering -- photon counting CT
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12174 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9347.xml