Phase‐based vascular input function: Improved quantitative DCE‐MRI of atherosclerotic plaques. Issue 8 (13th July 2015)
- Record Type:
- Journal Article
- Title:
- Phase‐based vascular input function: Improved quantitative DCE‐MRI of atherosclerotic plaques. Issue 8 (13th July 2015)
- Main Title:
- Phase‐based vascular input function: Improved quantitative DCE‐MRI of atherosclerotic plaques
- Authors:
- van Hoof, R. H. M.
Hermeling, E.
Truijman, M. T. B.
van Oostenbrugge, R. J.
Daemen, J. W. H.
van der Geest, R. J.
van Orshoven, N. P.
Schreuder, A. H.
Backes, W. H.
Daemen, M. J. A. P.
Wildberger, J. E.
Kooi, M. E. - Abstract:
- Abstract : Purpose: Quantitative pharmacokinetic modeling of dynamic contrast‐enhanced (DCE)‐MRI can be used to assess atherosclerotic plaque microvasculature, which is an important marker of plaque vulnerability. Purpose of the present study was (1) to compare magnitude‐ versus phase‐based vascular input functions (m‐VIF vs ph‐VIF) used in pharmacokinetic modeling and (2) to perform model calculations and flow phantom experiments to gain more insight into the differences between m‐VIF and ph‐VIF. Methods: Population averaged m‐VIF and ph‐VIFs were acquired from 11 patients with carotid plaques and used for pharmacokinetic analysis in another 17 patients. Simulations, using the Bloch equations and the MRI scan geometry, and flow phantom experiments were performed to determine the effect of local blood velocity on the magnitude and phase signal enhancement. Results: Simulations and flow phantom experiments revealed that flow within the lumen can lead to severe underestimation of m‐VIF, while this is not the case for the ph‐VIF. In line, the peak concentration of the m‐VIF is significantly lower than ph‐VIF ( p < 0.001), in vivo . Quantitative model parameters for m‐ and ph‐VIF differed in absolute values but were moderate to strongly correlated with each other [ K trans Spearman's ρ > 0.93 ( p < 0.001) and vp Spearman's ρ > 0.58 ( p < 0.05)]. Conclusions: m‐VIF is strongly influenced by local blood velocity, which leads to underestimation of the contrast medium concentration.Abstract : Purpose: Quantitative pharmacokinetic modeling of dynamic contrast‐enhanced (DCE)‐MRI can be used to assess atherosclerotic plaque microvasculature, which is an important marker of plaque vulnerability. Purpose of the present study was (1) to compare magnitude‐ versus phase‐based vascular input functions (m‐VIF vs ph‐VIF) used in pharmacokinetic modeling and (2) to perform model calculations and flow phantom experiments to gain more insight into the differences between m‐VIF and ph‐VIF. Methods: Population averaged m‐VIF and ph‐VIFs were acquired from 11 patients with carotid plaques and used for pharmacokinetic analysis in another 17 patients. Simulations, using the Bloch equations and the MRI scan geometry, and flow phantom experiments were performed to determine the effect of local blood velocity on the magnitude and phase signal enhancement. Results: Simulations and flow phantom experiments revealed that flow within the lumen can lead to severe underestimation of m‐VIF, while this is not the case for the ph‐VIF. In line, the peak concentration of the m‐VIF is significantly lower than ph‐VIF ( p < 0.001), in vivo . Quantitative model parameters for m‐ and ph‐VIF differed in absolute values but were moderate to strongly correlated with each other [ K trans Spearman's ρ > 0.93 ( p < 0.001) and vp Spearman's ρ > 0.58 ( p < 0.05)]. Conclusions: m‐VIF is strongly influenced by local blood velocity, which leads to underestimation of the contrast medium concentration. Therefore, it is advised to use ph‐VIF for DCE‐MRI analysis of carotid plaques for accurate quantification. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 8(2015)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 8(2015)Part 1
- Issue Display:
- Volume 42, Issue 8, Part 1 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2015-0042-0008-0001
- Page Start:
- 4619
- Page End:
- 4628
- Publication Date:
- 2015-07-13
- Subjects:
- biomedical MRI -- blood -- image enhancement -- medical image processing -- phantoms
Flow imaging -- Clinical applications -- Edge enhancement
Involving electronic [emr] or nuclear [nmr] magnetic resonance, e.g. magnetic resonance imaging -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Image enhancement or restoration, e.g. from bit‐mapped to bit‐mapped creating a similar image
carotid atherosclerosis -- vascular input function -- dynamic contrast‐enhanced MRI -- pharmacokinetic modeling
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4924949 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9335.xml