Technical Note: Confirming the prescribed angle of CT localizer radiographs and c‐arm projection acquisitions. Issue 2 (20th January 2016)
- Record Type:
- Journal Article
- Title:
- Technical Note: Confirming the prescribed angle of CT localizer radiographs and c‐arm projection acquisitions. Issue 2 (20th January 2016)
- Main Title:
- Technical Note: Confirming the prescribed angle of CT localizer radiographs and c‐arm projection acquisitions
- Authors:
- Szczykutowicz, Timothy P.
Labby, Zacariah E.
Rubert, Nicholas
Wallace, Charles - Abstract:
- Abstract : Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x‐ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c‐arm based CT systems. Methods: A mathematical expression relating the x‐ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c‐arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.
- Is Part Of:
- Medical physics. Volume 43:Issue 2(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 2(2016)
- Issue Display:
- Volume 43, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2016-0043-0002-0000
- Page Start:
- 865
- Page End:
- 869
- Publication Date:
- 2016-01-20
- Subjects:
- computerised tomography -- diagnostic radiography
Computed radiography
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers
quality assurance -- quality control -- computed tomography -- cone beam CT
Radiography -- Image sensors -- Cone beam computed tomography -- Image scanners -- X‐ray detectors -- Brachytherapy -- Image detection systems
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4940124 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9345.xml