Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71. Issue 3 (26th February 2014)
- Record Type:
- Journal Article
- Title:
- Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71. Issue 3 (26th February 2014)
- Main Title:
- Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71
- Authors:
- Gibbons, John P.
Antolak, John A.
Followill, David S.
Huq, M. Saiful
Klein, Eric E.
Lam, Kwok L.
Palta, Jatinder R.
Roback, Donald M.
Reid, Mark
Khan, Faiz M. - Abstract:
- Abstract : A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source‐surface distance (SSD) and source‐axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D 0 ′, that is determined for each userˈs photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D 0 ′ = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy‐dependent D 0 ′ ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d m, with D 0 ′ = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although someAbstract : A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source‐surface distance (SSD) and source‐axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D 0 ′, that is determined for each userˈs photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D 0 ′ = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy‐dependent D 0 ′ ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d m, with D 0 ′ = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air‐gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 3(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 3(2014)
- Issue Display:
- Volume 41, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2014-0041-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-02-26
- Subjects:
- Dosimetry/exposure assessment -- Therapeutic applications -- Electron and positron beams
dosimetry -- electron beams -- laser beams -- phantoms -- protocols -- radiation therapy -- water
monitor unit -- dose calculation -- photon beams -- electron beams
Radiation therapy -- Scintigraphy
Dosimetry -- Field size -- Collimators -- Photons -- Physicists -- Intensity modulated radiation therapy -- Ionization chambers -- Electron beams -- Multileaf collimators -- Collimation
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4864244 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9340.xml